Others SiE18-201
308 Caution Before Operation
3.2.3 Centralized Control (For KRC72, KRP411A1S and KRP410A11S)
For an explanation on usage, see the option handbook. However, do the following when using
the KRP410A11S (Contact connection centralized control PC board).
Note : The power failure recovery function is controlled by the ON signal from the centralized control
PC Board. The following may occur if the unit is used without cutting jumper JC.
If the unit was running when a power failure occurred, it may not resume operation after
recovering from a power failure.
3.2.4 Dry Keep Change-over Switch (All Indoor Models)
For Cooling Only and Heat Pump Model
Cut jumper JC on the indoor PC Bord.
(ML112)
Jumper
(On indoor PC
Board)
Function When connected
(factory set)
When cut
JC Power failure
recovery function
Auto start Unit does not resume operation
after recovering from a power
failure. Timer ON-OFF settings are
cleared.
JB Fan speed setting
when compressor is
OFF on thermostat.
Fan speed setting ;
Remote controller
setting
Fan rpm is set to “0”
<Fan stop>