SiE18-201 Main Functions
Main Functions 49
1.1.25 Emergency Operation Function (ON/OFF Switch)
The unit can be turned ON only by pressing ON/OFF operation switch. This is convenient when
the remote controller cannot be found or if the batteries are dead.
The operation condition is as follows:
Pressing the switch again will turn the unit OFF.
1.1.26 Powerful Operation
During cool and program dry operation, when the POWERFUL button on the remote controller
is pressed, the thermistor setting is changed to the lowest setting of the remote controller and
the fan runs at the maximum rpm (Note). During fan operation, air is blown at the maximum fan
rpm.
Note: Max. fan rpm = H tap set by remote controller + 50 rpm
Notes on POWERFUL Operation
In COOL mode
To maximize the cooling effect, the temperature setting is fixed to 18˚C and the air flow rate
is fixed to the maximum setting. (H tap + 50 r.p.m)
The temperature and air flow settings are not variable.
In DRY mode
The temperature setting is lowered by 3˚C and the air flow rate is slightly increased. You can
repeat POWERFUL operation if you need even more dehumidification.
Operation mode Cool
Fan speed Auto
Set temperature 22˚C
ON/OFF button
Operation lamp
(Green) (Yellow) (Red)
Receiver
(M1102)
ON/OFF button
Timer lamp Cleaning lamp