Outdoor Unit SiE18-201
284 Removal Procedure
2.6 Removal of Sound Insulation
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step Procedure Points
Remove the terminal
cover and disconnect the
compressor leads,
referring to the
instructions in "Removal
of PCB".
1. Disconnecting the
peripheral components
1
Detach the compressor
mounting plate.
2
Slide up the cover at
the back of the partition
board. Release the
cover off the two
hooks.
The partition board cannot
be detached.
3
Remove the screw
from the partition
board.
4
Open the partition
board to the left to
easily access the
sound insulation.
2. Detaching the sound
insulation
1
Undo the sound
insulation fixture string.
2
Draw out the sound
insulation cover and
sound insulation from
the top of the
compressor.
Compressor
mounting plate
(M1202)
Cover
(M1203)
Partition
board
Partition
board
(M1204)
Sound
insulation
cover
Fixture
string
(M1205)
Sound insulation cover
(M1206)
Page view 294
1 2 ... 290 291 292 293 294 295 296 297 298 299 300 ... 343 344