Specifications SiE18-201
12 Specifications
1.1.2 Heat Pump
Notes:
1. Refer to Engineering Data Book.
2. The data are based on the conditions shown in the table below.
50Hz 220-240V / 60Hz 220-230V
Model
RMX140JVMC9 (8)
Cooling Heating
Cooling Capacity (19.0˚CWB)
kW 14.5 16.5
kcal/h 12,470 14,190
Power Consumption W5,000 5,780
Running Current A 23.2 26.8
Casing Color Ivory White
Compressor
Type Hermetically Sealed Scroll Type (Oval Discharge)
Model JT100FBVD
Motor Output W 3,300
Refrigerant
Oil
Model SUNISO 4GSD.I.
Charge L 1.5
Refrigerant
Type R22
Charge kg 9.9
Air Flow Rate
m³/min
H 114
L 104
cfm
H4,024
L3,671
Fan
Type Propeller
Motor Output W (Upper Side) H : 53 L : 38 (Lower Side) H : 41 L : 30
Running Current A (Upper Side) H : 0.50 L : 0.45 (Lower Side) H : 0.47 L : 0.42
Power Consumption W (Upper Side) H : 93.1 L : 78.8 (Lower Side) H : 81.3 L : 68.8
Power Factor % 100
Starting Current A 29.0
Dimensions (H×W×D) mm 1,345×880×320
Package Dimensions mm 918×394×1,397
Weight kg 136
Gross Weight kg 145
Operation Sound dBA 53
Piping
Connection
Liquid mm φ 9.5 (Flare Connection)
Gas mm φ19.1 (Flare Connection)
Drain mm φ18
Heat Insulation Both Liquid and Gas Pipes
No. of Wiring Connection 3 for Power Supply, 4 for Interunit Wiring (Including Earth Wiring)
Max. Interunit Piping Length m
115 (Total Main Piping and Branch Piping)
55 (Total Main Piping), 60 (Total Branch Piping)
15 (Max. Length for Each Room)
Amount of Additional Charge g/m Chargeless
Max. Installation Height Difference m 30 (Between Indoor or BP Unit and Outdoor Unit), 15 (Between Indoor or BP Units)
Drawing No. 3D030946A
Cooling Heating Piping Length
Indoor ; 27˚CDB / 19.0˚CWB
Outdoor ; 35˚CDB
Indoor ; 21˚CDB
Outdoor ; 7˚CDB / 6˚CWB
Main Piping : 5m
Branch Piping : 3m
(each indoor unit / 71 Class+60 Class)
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
BP Unit
Outdoor Unit
Main Piping
Branch Piping
Indoor Unit
(Q0143)