Daikin J Series Service Manual Page 313

  • Download
  • Add to my manuals
  • Print
  • Page
    / 344
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 312
Wiring SiE18-201
302 Caution Before Operation
2.3 Outdoor Unit Rotary Switch Setting
* RAM View Monitor
RSW1 RSW2 Remarks Unit
00Latest (status) error code Error code
01Latest (status) error spot Standard
02Current run mode Status
03Current 4-way valve Status
04Current operating frequency (Hz) Frequency
05Current EVP EV openness
06Current EVG EV openness
07Current EVL EV openness
08Current fan (upper) Fan rpm
09Current fan (lower) Fan rpm
10Current input current Ampere
11Current total input current Ampere
12Current high pressure (calculated) Pressure
13Current suction pressure Pressure
14Current outdoor temperature Temp. offset 40h
15Current discharge temperature Temperature
16Current suction temperature Temp. offset 40h
17Current outdoor heat exchange temperature Temp. offset 40h
18Current outdoor fluid pipe temperature Temp. offset 40h
19Current fin temperature Temperature
20Current box temperature Temp. offset 40h
21Current BP 1 Room-A motorized valve openness EV openness
22Current BP 1 Room-B motorized valve openness EV openness
23Current BP 1 Room-C motorized valve openness EV openness
24Current BP 2 Room-A motorized valve openness EV openness
25Current BP 2 Room-B motorized valve openness EV openness
26Current BP 2 Room-C motorized valve openness EV openness
27Current BP 3 Room-A motorized valve openness EV openness
28Current BP 3 Room-B motorized valve openness EV openness
29Current BP 3 Room-C motorized valve openness EV openness
30
31Current BP 1 Room-A fluid pipe temperature Temp. offset 40h
32Current BP 1 Room-B fluid pipe temperature Temp. offset 40h
33Current BP 1 Room-C fluid pipe temperature Temp. offset 40h
34Current BP 2 Room-A fluid pipe temperature Temp. offset 40h
35Current BP 2 Room-B fluid pipe temperature Temp. offset 40h
36Current BP 2 Room-C fluid pipe temperature Temp. offset 40h
37Current BP 3 Room-A fluid pipe temperature Temp. offset 40h
38Current BP 3 Room-B fluid pipe temperature Temp. offset 40h
39Current BP 3 Room-C fluid pipe temperature Temp. offset 40h
Switch Bo
Setting Position
x
Service Monitor
7 seg. display
SW1
SW1, SW2
SW2
(Q0008)
Page view 312