1.1.23 Air Flow Automatic (Auto Fan Speed)
In cooling operation, if automatic airflow has been selected, the wind flow is determined
according to the room temperature and the temperature setting.
1.1.24 Night Set Mode Function
This mode automatically keeps temperature slightly higher than the temperature setting. In this
way, there is no need to worry about overcooling while sleeping, and it also saves on electricity.
Set the OFF timer.
The unit will cool the room at the set temperature for 1 hour from when the timer
starts counting.
After that, the unit will raise temperature 0.5˚C higher than the set temperature and
cool for 30 minutes.
After that, the unit will raise temperature another 0.5˚C and continue cooling at that
temperature.
Setting the OFF timer forcibly changes the airflow adjustment to the tap-L setting.
It is possible to change the airflow setting while the OFF timer is in operation.
However, changing the airflow setting cancels the shift-up of the set temperature.
Note: No higher temperature setting on program Dry or Auto operation.
BLADE ANGLE
UP/DOWN : (AUTOMATIC)
COOLING DRY
RIGHT/LEFT : (MANUAL)
FLAP
45˚
45˚
20˚
40˚
20˚
40˚
(RL005)
0.5˚C
0.5˚C
30-minutes
60-minutes