Main Functions SiE18-201
38 Main Functions
1. Main Functions
1.1 Main Functions in Split Type
1.1.1 Wide Angle Flaps, Louvers and Auto-Swing
For FTX25/35J
Series Only
Outline of the
Action
It can be commanded for J type by means of a user setting to select either any one desired
position among the five-step directions of air flow adjusted on a remote controller, or Auto-
swing.
Although the liquid crystal display of the five-step directions of the air flow is common for the
modes of Cooling·Dry/Heating as illustrated above, in fact the range of the swing angle is
slightly different in every operation mode.
The position a user sets will be selected among the five positions calculated preliminarily and
evenly divided into four partitions which were taken from the upper and lower flap angle’s range
limits of each mode.
When Auto-swing is chosen, the flap swings in the swing range which meets the operation
mode selected.
Others The vertical louver can be adjusted manually. The movable range is 60 degrees for left or
right, and total 120 degrees.
A diffuser is not available for J type.
1
2
3
4
5
Initial
(RL006)
Fan mode is available for the models of cooling-only.
20˚
45˚
Heating mode
0 degree based on
the horizontal line.
(RL007)
25˚
Cooling /Dry mode
0 degree based on
the horizontal line.
(RL008)
10˚
45˚
0 degree based on
the horizontal line.
Fan mode
(RL009)