Daikin J Series Service Manual Page 26

  • Download
  • Add to my manuals
  • Print
  • Page
    / 344
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 25
SiE18-201 Specifications
Specifications 15
Notes:
1. Refer to Engineering Data Book.
2. The data are based on the conditions shows in the table below.
50Hz 220-230-240V / 60Hz 220-230V
Model
RMX140JZVMB
Cooling Heating
Cooling Capacity (19.0˚CWB)
kW 14.5 16.5
kcal/h 12,470 14,190
Power Consumption W5,000 6,050
Running Current A 23.2-22.2-21.3 28.1-26.8-25.7
Casing Color Ivory White
Compressor
Type Hermetically Sealed Scroll Type (Oval Discharge)
Model JT100FAVD
Motor Output W 3,300
Refrigerant
Oil
Model DAPHNE FVC68D
Charge L 1.5
Refrigerant
Type R407C
Charge kg 9.9
Air Flow Rate
m³/min
H 114
L 104
cfm
H4,024
L3,671
Fan
Type Propeller
Motor Output W (Upper Side) H : 53 L : 38 (Lower Side) H : 41 L : 30
Running Current A (Upper Side) H : 0.50 L : 0.45 (Lower Side) H : 0.47 L : 0.42
Power Consumption W (Upper Side) H : 93.1 L : 78.8 (Lower Side) H : 81.3 L : 68.8
Power Factor % 100
Starting Current A 29.0
Dimensions (H×W×D) mm 1,345×880×320
Package Dimensions (W×D×H) mm 918×394×1,397
Weight kg 136
Gross Weight kg 145
Operation Sound dBA 53
Piping
Connection
Liquid mm φ9.5 (Flare Connection)
Gas mm φ19.1 (Flare Connection)
Drain mm φ18
Heat Insulation Both Liquid and Gas Pipes
No. of Wiring Connection 3 For Power Supply, 4 For Interunit Wiring (Included Earth Wiring)
Max. Interunit Piping Length m
115 (Total Main Piping and Branch Piping)
55 (Total Main Piping), 60 (Total Branch Piping)
15 (Max. Length for Each Room)
Amount of Additional Charge g/m Chargeless
Max. Installation Height Difference m 30 (Between Indoor or BP Unit and Outdoor Unit), 15 (Both between Indoor Units and BP Units)
Drawing No. 3D031578
Cooling Heating Piping Length
Indoor ; 27˚CDB / 19.0˚CWB
Outdoor ; 35˚CDB
Indoor ; 21˚CDB
Outdoor ; 7˚CDB / 6˚CWB
Main Piping : 5m
Branch Piping : 3m
(each indoor unit / 71 Class+60
Class)
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
BP Unit
Outdoor Unit
Main Piping
Branch Piping
Indoor Unit
(Q0143)
Page view 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 343 344

Comments to this Manuals

No comments