EDUS04-906_b Optional Accessories
Room Air Conditioners H-Series 73
Installation
This product is available in two types. The KRP413A1S · KRP413AA1S is for installation in a case independent of the indoor unit, and
the KRP413A1 is for installation within the indoor unit.
1. KRP413A1S · KRP413AA1S
1 Installation diagram
Indoor unit PCB
Adaptor case
wiring
Local wiring or
power cord, etc.
S21
2 Components
Adaptor case assy Wiring (approx. 0.8 m)
(Adaptor (PCB) is attached in the adaptor case.)
Accessories
• Binding band (4 pcs.)
• Securing tape for attaching to the indoor unit (2 sets)
• Screws for attaching the adaptor case (4 pcs.)
• Screws for attaching to the wall (3 pcs.)
Installation manual
2. KRP413A1
For this type, install the adaptor PCB within the indoor unit. The method of
installation and connection vary depending on the model of the air
conditioner. See your air conditioner installation manual for details.
1 Components
Adaptor PCB Wiring (approx. 0.25 m)
Installation manual
3.
Attaching Adaptor Case Assy (for KRP413A1S · KRP413AA1S)
1 Using the screws (to mount on a wall, etc.)
Use the 3 supplied screws to attach the case assy .
Indoor unit
Adaptor case
Install the adaptor case assy as close to the indoor unit as possible.
Removing case front
Adaptor PCB
Case front
Screw
Screw cover
Remove the screw cover, one of the screws
and then the case front.
Attach the case back to the surface by
tightening the screws through the screw
holes (one round hole, two long holes).
After connecting the cables (refer to the following sections), replace the
case front. Be careful not to damage the wiring in the case.
Wiring
Press in so that the prong catches
the case back.
Screw
Screw cover
2 Using securing tape (to attach on the indoor unit)
Attach the adaptor case with the supplied securing tape.
Remove the case front (as for mounting on a wall).
After connecting the cables (see the following sections), replace the
case front. It can be screwed to the case back from the rear with the
four supplied screws.
Be careful not to damage the wiring in the case.
Attach the hook side (loop side) of the included securing tape to the rear
surface of the HA case, then attach the loop side (hook side) to the top of
the air conditioner unit spaced at the same intervals.
Securing tape
Hook side (loop side)
Securing tape
Loop side (hook side)
Indoor unit
To prevent the adaptor case assy from falling, do not use the securing
tape for attaching it to a wall or other surface.