Installation Manual EDUS04-906_b
26 Room Air Conditioners H-Series
6
1.
Installing the mounting plate.
The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring
points on the wall.
2) Secure the mounting plate to the wall with screws.
Recommended mounting plate retention spots and Dimensions
2.
Boring a wall hole and installing wall embedded pipe.
For walls containing metal frame or metal board, be sure to use a wall
embedded pipe and wall cover in the feed-through hole to prevent possible
heat, electrical shock, or fire.
Be sure to caulk the gaps around the pipes with caulking material to prevent
water leakage.
1) Bore a feed-through hole of φ2-9/16 inch (65mm) in the wall so it has a down
slope toward the outside.
2) Insert a wall pipe into the hole.
3) Insert a wall cover into wall pipe.
4) After completing refrigerant piping, wiring, and drain piping, caulk pipe hole
gap with putty.
3.
Installing inter-unit wiring.
1) Open the front panel and remove the service lid.
2) Pull out the inter-unit wiring from the back of the
indoor unit to the front. It is easier to pull out if
bending up the wire edge in advance.
3) To connect the inter-unit wiring after hooking the unit
onto the mounting plate, connect the inter-unit
wiring as shown in the figure at right.
A
A
A
(Bolt size : 3/8 (M10))
6-1/2 (165) 11-3/16 (285)
5-11/16 (145)
1-3/4
(45)
9/16
(14.5)
12 (305)
1-3/4
(44.5)
10-1/4 (260.5)
1-3/4
(44.5)
1-7/16 (36.5)
5-15/16
(150)
3-15/16
(100)
15-3/16 (385)
15-3/16 (385)
6-11/16
(170)
11-15/16 (302.5)
21-9/16 (548)
23-9/16 (598)
5/8
(15)
35-1/16 (890)
7/16
(12)
4-3/4
(120)
Removed pipe
port cover
A
Mounting plate
* The removed pipe port cover can be
kept in the mounting plate pocket.
Use tape
measure
as shown.
Position the
end of a tape
measure at ∇.
Liquid pipe end
Gas pipe end
Keep here the piece cut out
from the unit for piping
Through the wall
hole φ2-9/16 (65)
Drain hose
position
Through the wall
hole φ2-9/16 (65)
Drain hose
position
φ2-9/16 (65)φ2-9/16 (65)
Place a leveler on raised tab.
Recommended
mounting plate
retention spots
(9 spots in all)
(Bolt size : 3/8 (M10))
A
unit : inch (mm)
Inside Outside
Caulking
Wall embedded pipe
(Field supply)
Wall hole cover
(Field supply)
Wall embedded pipe
(Field supply)
φ2-9/16 (65)
Inter-unit wiring
Hang indoor
unit’s hook here.
Lift the indoor unit slightly
by placing it on packing
or other similar materials.
When stripping the ends of
inter-unit wiring in advance,
bind right ends of wires with
insulation tape.
Pull down using caution not
to catch the inter-unit wiring.
A
Indoor Unit Installation