Installation Manual EDUS04-906_b
30 Room Air Conditioners H-Series
10
Indoor Unit Installation
7.
Drain piping.
1) Connect the drain hose, as described right.
2) Remove the air filters and pour some water into the drain pan to check the water
flows smoothly.
3) When drain hose requires extension, obtain an extension hose commercially
available.
Be sure to thermally insulate the indoor section of the extension hose.
4) When connecting a rigid polyvinyl chloride pipe
(nominal diameter 1/2 inch (13mm)) directly to the
drain hose attached to the indoor unit as with
embedded piping work, use any commercially
available drain socket (nominal diameter 1/2 inch
(13mm)) as a joint.
8.
Improving installation strength.
We recommend screwing the indoor unit onto a
mounting plate in order to improve the
installation strength.
1) Remove the front grille.
2) Screw in the indoor unit with fixing screws.
3) Attach the front grille.
The drain hose should
be inclined downward.
No trap is permitted.
Do not put the end
of the hose in water.
Indoor unit
drain hose
f11/16”
(f18mm)
Extension drain hose
Heat insulation tube
(Field supply)
Drain hose supplied with
the indoor unit
Commercially available drain
socket
(nominal diameter 1/2 inch
(13mm))
Commercially available rigid
polyvinyl chloride pipe
(nominal diameter 1/2 inch
(13mm))
f11/16”
(f18mm)
Shape of
rear side of
indoor unit
Wall
Piping
Indoor unit
Screw position
A
Mounting plate
A
Mounting plate
Screw in
D
Fixing screw
3/16” × 1/2”L (M4 × 12mm)
Front diagram Enlarged diagram
Screw position
A
D