EDUS04-906_b Installation Manual
Room Air Conditioners H-Series 27
7
4.
Laying piping and wiring.
Lay the piping and drain hose according to the
orientation of the piping coming out of the unit, as shown
below.
Make sure the drain hose is sloped downward.
Wrap the piping and drain hose together using insulation
tape.
4-1. Right-side, right-back, or right-bottom piping.
1) Wrap the piping and inter-unit wiring using insulation tape as shown in the piping bundle diagram.
2) Put all the pipes through the through-hole in the wall and hook the indoor unit onto the mounting plate.
3) Connect the pipes.
4-2. Left-side, left-back, or left-bottom piping.
1) Replace the drain plug and drain hose. (How to replace the drain plug
and drain hose.)
2) Pull in the refrigerant piping and lay it so that it matches the liquid and
gas piping marked on the mounting plate.
3) Hook the indoor unit onto the mounting plate.
4) Connect the pipes. If it is difficult to do, remove the front panel first.
5) Wrap the insulation on the piping with insulation tape. If you are not
replacing the drain hose, store it in the location shown below.
4-3. Left-back piping.
Drain hose
Gas pipe
Liquid pipe
Inter-unit wiring
Insulation tape
Piping bundle diagram
Cut out the
piping-through hole.
Install with a
downward slope.
Cut out the
piping-through hole.
• Right-back piping • Right-bottom piping• Right-side piping
It is recommended
to use the elbow.
A
• Left-back piping • Left-bottom piping• Left-side piping
Cut out the
piping-through hole.
Refrigerant pipe
Drain hose
Refrigerant pipe
Cut out the
piping-through hole.
Refrigerant pipe
D
3/16” × 1/2”L (M4 × 12mm)
1) Remove the front grille.
2) Secure the indoor unit
with the indoor unit
fixing screws.
3) Install the front grille.
When securing the indoor unit with screws
D
A
A
Inter-unit wiringDrain hose
Caulk this hole with putty
or caulking material.
Bind with plastic tape.
Wrap insulation tape around the
bent portion of refrigerant pipe.
Overlap at least half the width
of the tape with each turn.
Mounting plate
A