Daikin Quaternity H-Series Specifications Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 80
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
EDUS04-906_b Specifications 60Hz 230V
Room Air Conditioners H-Series 5
60Hz 230V
Note:
The data are based on the conditions shown in the table below.
Model
Indoor Units FTXG15HVJU
Outdoor Units
RXG15HVJU
Cooling Heating
Capacity
Rated (Min.~Max.)
Btu/h 15,000 (5,300~18,000) 18,000 (4,400~21,200)
Moisture Removal Pt/h 4.8
Running Current (Rated) A 5.64 6.36
Power Consumption Rated
(Min.~Max.)
W 1,160 (260~1,930) 1,320 (230~2,120)
Power Factor % 89.0 99.0
EER (Rated)
Btu/h·W
12.9
COP (Rated) W/W 3.99
Energy
Efficiency
SEER/HSPF 21.0 10.0
Piping
Connections
Liquid inch (mm) φ 1/4” (6.4 mmm)
Gas inch (mm) φ 3/8” (9.5 mm)
Drain inch (mm) φ 11/16
” (17.5 mm)
Heat Insulation Both Liquid and Gas Pipes
Max. Interunit Piping Length feet (m) 32’ (10 m)
Max. Interunit Height Difference feet (m) 26’ (8 m)
Chargeless feet (m)
Amount of Additional Charge of Refrigerant oz/ft
Indoor Unit FTXG15HVJU
Front Panel Color White
Airflow Rate cfm (m³/min)
H 487 (13.8) 494 (14.0)
M 371 (10.5) 392 (11.1)
L 258 (7.3) 293 (8.3)
Fan
Type Cross Flow Fan
Motor Output W 57
Speed Steps 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downward
Air Filter Removable / Washable / Mildew Proof
Running Current (Rated) A 0.15 0.16
Power Consumption (Rated) W 33 35
Power Factor % 95.7 95.1
Temperature Control Microcomputer Control
Dimensions (H×W×D) inch (mm) 12 × 35-1/16 × 8-1/4” (305 x 891 x 210 mm)
Packaged Dimensions (H×W×D) inch (mm) 11 × 37-5/8 × 14-7/8” (279 x 956 x 378 mm)
Weight Lbs(kg) 31 lbs (14 kg)
Gross Weight Lbs(kg) 38 lbs (17 kg)
Operation
Sound
H/M/L dBA 45 / 37 / 29 44 / 38 / 31
Outdoor Unit RXG15HVJU
Casing Color Ivory White
Compressor
Type Hermetically Sealed Swing Type
Model 2YC36CXD
Motor Output W 1,100
Refrigerant
Oil
Model FVC50K
Charge oz 13.5
Refrigerant
Model R-410A
Charge Lbs 3.1
Airflow Rate cfm (m³/min)
H 1,262 (35.7) 1,195 (33.8)
L—
Fan
Type Propeller
Motor Output W 60
Running Current (Rated) A 5.49 6.2
Power Consumption (Rated) W 1,127 1,285
Power Factor % 89.3 90.1
Dimensions (H×W×D) inch (mm)
22-3/8 × 31-5/16 ×11-1/4”
(568 x 795 x 286 mm)
Packaged Dimensions (H×W×D) inch (mm)
25-3/16 ×36-7/16 ×14-7/8”
(568 x 795 x 286 mm)
Weight Lbs (kg) 99
Gross Weight Lbs(kg) 104
Operation
Sound
H / L dBA 50 / — 50 / —
Drawing No. 3D062859
Cooling Heating Piping Length
Indoor ; 80°FDB/67°FWB
Outdoor ; 95°FDB/75°FWB
Indoor ; 70°FDB/60°FWB
Outdoor ; 47°FDB/43°FWB
25 ft (7.5 m)
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Page view 5
1 2 3 4 5 6 7 8 9 10 11 ... 79 80

Comments to this Manuals

No comments