EDUS04-906_b Installation Manual
Room Air Conditioners H-Series 23
3
Indoor Unit Installation Drawings
1.
Removing and installing indoor unit.
Installation method
1) Using the marks (3 locations) on top of the
indoor unit, attach the mounting plate hooks
onto the indoor unit.
2) Attach the tabs on the bottom frame onto the
mounting plate. If the tabs are not hooked onto
the plate, remove the front grille to hook them.
(Check to see if the tabs are hooked securely.)
Removal method
Push up the mark part on the bottom of the front
grille, discharge the tabs, and then remove the unit
while lifting it up.
Ta b
Bottom
frame
Mark
(rear side)
A Mounting
plate
To remove the unit, push up the bottom of the bottom
frame with your fingers to free tabs.
(Mark parts (2 locations) on the bottom of the front grille.)
A Mounting
plate
A
A
F
Remote
controller holder
Fixing screws for remote
controller holder
1/8” × 13/16”L (M3 × 20mm) (2)
Wrap the insulation
pipe with the finishing
tape from bottom to top.
Install the
hose with a
downward
slope.
Cut thermal insulation pipe
to an appropriate length and
wrap it with tape, making
sure that no gap is left in the
insulation pipe’s cut line.
1-3/16” (30mm)
or more
from ceiling
1-15/16” (50mm)
or more from walls
(on both sides)
Mounting plate fixing
screws 3/16” × 1”L (M4 × 25mm) (9)
A
Mounting plate
The mounting plate
should be installed on a
wall which can support the
weight of the indoor unit.
Use when
opening the
front panel and
securing.
Supporting plate
Supporting plate
How to open the service lid
Front panel
Air filter
2)
1)
The service lid is
removable.
Opening the lid
1) Remove the screws
on the service lid.
2) Hold the knobs on the
service lid and pull
forward.
Before screwing the
remote controller
holder to the wall,
make sure that control
signals are properly
received by indoor unit.
C
Titanium apatite
photocatalytic
air-purifying filter
B
Deodorizing filter
for streamer
Hook
E
Wireless
remote controller
Set the
dry batteries
AAA. LR03
(alkaline)
G
L
The securing tape is applied.
Be sure to remove it before
installation.
A
K
Page view 23