Main Functions SiBE041010
22 Function and Control
1.8 ECONO Operation
Outline The "ECONO operation" reduces the maximum operating current and power consumption
during start-up etc..
This operation is particularly convenient for energy-saving-oriented users. It is also a major
bonus for those whose breaker capacities do not allow the use of multiple electrical devices and
air conditioners.
It is easily activated from the wireless remote controller by pushing the ECONO button.
When this function is activated, the maximum capacity decreases.
The remote controller can send the ECONO command when the unit is in COOL, HEAT,
DRY, or AUTO operation. This function can only be set when the unit is running. Pressing
the ON/OFF button on the remote controller cancels the function.
This function and POWERFUL operation cannot be used at the same time. The latest
command has the priority.
Detail
When the ECONO command is valid, the input current is under reducing control.
(Refer to "Input current control" on page 31.)
ECONO Operation
(R12013)
Normal
Maximum during normal operation
Maximum during ECONO operation
Time
Power
consumption
and current
Page view 31