SiBE041010 Main Functions
Function and Control 23
1.9 Inverter POWERFUL Operation
Outline In order to exploit the cooling and heating capacity to full extent, operate the air conditioner by
increasing the indoor fan rotating speed and the compressor frequency.
Detail When POWERFUL button is pressed, the fan speed and target temperature are converted to
the following states for 20 minutes.
Ex.) : POWERFUL operation in cooling mode.
Operation mode Fan speed Target temperature
COOL H tap + 80 rpm 18°C
DRY DRY rotating speed + 80 rpm Lowered by 2.5°C
HEAT H tap + 80 rpm 31°C
FAN H tap + 80 rpm
AUTO Same as cooling / heating in
POWERFUL operation
The target temperature is kept
unchanged.
(R11976)
Target temp.
Fan
80 rpm
18˚C
POWERFUL ON
POWERFUL OFF
H tap
Set tap
It should be the lower limit of cooling temperature.
It counts 20 min. also in the remote controller.
20 minutes
Ending condition: "or" in 1 to 3
1. After the lapse of 20 minutes.
2. Operation OFF
3. POWERFUL operation is OFF.