SiBE041010 Main Functions
Function and Control 15
Inverter Features The inverter provides the following features:
The regulating capacity can be changed according to the changes in the outdoor
temperature and cooling / heating load.
Quick heating and quick cooling
The compressor rotational speed is increased when starting the heating (or cooling). This
enables to reach the set temperature quickly.
Even during extreme cold weather, the high capacity is achieved. It is maintained even when
the outdoor temperature is 2°C.
Comfortable air conditioning
A fine adjustment is integrated to keep the room temperature constant.
Energy saving heating and cooling
Once the set temperature is reached, the energy saving operation enables to maintain the
room temperature at low power.
Frequency Limits The following functions regulate the minimum and maximum frequency:
Forced Cooling
Operation
Refer to “Forced operation mode” on page
39
for detail.
Frequency Functions
Low Four way valve operation compensation. Refer to page 29.
High Compressor protection function. Refer to page 30.
Discharge pipe temperature control. Refer to page 30.
Input current control. Refer to page 31.
Freeze-up protection control. Refer to page 32.
Heating peak-cut control. Refer to page 32.
Defrost control. Refer to page 34.
Page view 24