SiBE041010 Indoor Unit
Removal Procedure 101
1. Indoor Unit
1.1 Removal of Air Filter
Procedure Warning Be sure to wait 10 minutes or more after turning off all power
supplies before disassembling work.
Step Procedure Points
1. Appearance feature
Warning
Dangerous: High voltage
A high voltage is applied to
all the electric circuits of this
product including
thermistors.
When a signal from the
remote controller is
received, the receiving tone
sounds and the operation
lamp flickers immediately to
confirm the signal reception.
When the ON/OFF button is
kept pressed for 5 seconds,
the forced cooling operation
is performed for about 15
minutes.
2. Remove the air filter.
1
Open the front panel to
the position where it
stops.
2
Slightly push up the
knob at the center of
the air filter.
The air filter is not marked
for difference between the
right and left sides.
The air filter can be set
easily by inserting it along
the guides.
Insert the air filter with the
“FRONT” mark faced up.
Be sure to insert the hooks
(at 2 lower positions) when
mounting the air filter.
Room temperature thermistor
(R7980)
ON/OFF
Signal receiver
ON/OFF button
(Forced operation ON/OFF button)
(R7981)
Operation
lamp
TIMER
lamp
Front panel
Hooks
(R7982)
Air filter