SiE25-110 Specifications
Specifications 17
FAYP (Wall Mounted Type)
Notes: 1. Nominal capacities are based on the following conditions:
2. AFR(Air flow rate) is shown at 220V~240V.
3. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
4. In case of drain piping for outdoor unit, drain piping kit (option) is needed.
Model
Indoor Units FAYP71BV1 FAYP100BV1
Outdoor Units RZP71DV1 RZP100DV1
1 Cooling Capacity
kW 7.1 (3.3~8.0) 10.0 (5.0~11.4)
Btu/h 24,200 (11,200~27,300) 34,100 (17,000~38,900)
kcal/h 6,100 (2,800~6,800) 8,600 (4,300~9,800)
1 Heating Capacity
kW 8.0 (3.5~9.0) 11.2 (5.6~12.8)
Btu/h 27,300 (11,900~30,700) 38,200 (19,100~43,600)
kcal/h 6,800 (3,000~7,700) 9,600 (4,800~11,000)
Indoor Units FAYP71BV1 FAYP100BV1
Color White White
Dimensions H×W×Dmm 360×1,570×200 360×1,570×200
Coil
Type Cross Fin Coil (Multi Louver Fins and N-hixTubes)
Row×Stages×Fin Pitch 2×12×1.4 2×12×1.4
Face Area m² 0.332 0.332
Fan
Model QCL1163MA+QCL1163MB QCL1163MA+QCL1163MB
Type Cross Flow Fan Cross Flow Fan
Motor Output W 46 49
Air Flow Rate m³/min. (H) 19 (L) 16 (H) 23 (L) 19
Air Filter
Machine Weight kg 26 26
Piping
Connections
Liquid mm
φ9.5 (Flare) φ9.5 (Flare)
Gas mm
φ15.9 (Flare) φ19.1 (Flare)
Drain mm I. D
φ20×O. Dφ26 I. Dφ20×O. Dφ26
Remote Controller
(Option)
Wired BRC1C61 BRC1C61
Wireless BRC7C610W BRC7C610W
Outdoor Units RZP71DV1 RZP100DV1
Color Pale Ivory Pale Ivory
Dimensions H×W×Dmm 905×900×320 1,435×900×320
Coil
Type Cross Fin Coil (Waffle Fins and NHi-XA Tubes)
Row×Stages×Fin Pitch 2×40×1.4 2×64×1.4
Face Area m² 0.991 1.598
Comp.
Model 2YC63AXD JT100FAVD
Type Hermetically Sealed Swing Type Hermetically Sealed Scroll Type
Motor Output kW 1.9 1.9
Fan
Model P47M11F P47M11F×2
Type Propeller Propeller
Motor Output W 55 55+55
Air Flow Rate m³/min. 53 97
Machine Weight kg 71 119
Piping
Connections
Liquid mm
φ9.5 (Flare) φ9.5 (Flare)
Gas mm
φ15.9 (Flare) φ19.1 (Flare)
Drain mm
φ26.0 (Hole) φ26.0 (Hole)
Safety Devices High Pressure Switch. Fuse.
Capacity Control Compressor Revolution Speed Control (Inverter System)
Refrigerant Control Expansion Valve (Electronic Type)
Ref.Piping
Max. Length m 50 (Equivalent Length 70m) 70 (Equivalent Length 90m)
Max. Height Difference m 30 30
Refrigerant
Model R-407C R-407C
Charge kg 3.2 (Charged for 30m) 5.0 (Charged for 30m)
Ref. Oil
Model DAPHNE FVC50K DAPHNE FVC68D
Charge L 0.65 1.2
Drawing No. C : 4D034214
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Cooling Heating Piping length Hz-Volts
Indoor: 27˚CDB, 19.0˚CWB
Outdoor: 35˚CDB, 24˚CWB
Indoor: 20˚CDB, 15˚CWB
Outdoor: 7˚CDB, 6˚CWB
7.5m
(Horizontal)
50Hz~230V