Page view 284
SiEBE12-625 Outdoor Unit (68 / 75 Class)
Removal Procedure 275
2.2 Removal of Electrical BOX
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Removing the tie wires
Remove the piping in the
backward direction.
1 The figure shows the tie
pipe connections.
2
Remove the terminal
board fitting screw.
Match the colours of the tie
wires to A, B, C and D ports
as follows.
(1) - Black Power
(2) - White Power
(3) - Red Transmission
Wires are fixed to the
terminal board with screws.
Terminal board is made of
integral moulded resin.
Electrical box
Service monitor PCB
Electronic expansion
valve coils
Service port
A port
B port
C port
D port
Outdoor air thermistor
Fluid pipes
Gas pipe
Terminal board fitting screw
Power terminal
board
(L) - White
(N) - Black
Earth terminal
screw
Wiring fixture
A port
D port
C port
B port
Page view 284