Daikin FBQ71C7VEB User Manual

Browse online or download User Manual for Split-system air conditioners Daikin FBQ71C7VEB. Daikin Air Conditioner FBQ71C7VEB

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - RZQS-DV1

technical dataSplitSky Airair conditioning systemsRZQS-DV1EEDEN09-100

Page 2 - Split - Sky Air

314• Split Sky Air • Outdoor Units10• Outdoor Units • R-410A • RZQS-DV14 OptionsRZQ(S)71-140DV13TW26739-1FName of optionKit nameRZQ71D7V1B RZQ100D7V1B

Page 3

• Outdoor Units • R-410A • RZQS-DV115• Split Sky Air • Outdoor Units115 Capacity tables5 - 1 Combination tableRZQ(S)71-140DV1Multi Combination Possibi

Page 4 - TABLE OF CONTENTS

315• Split Sky Air • Outdoor Units12• Outdoor Units • R-410A • RZQS-DV15 Capacity tables5 - 2 Cooling capacity tablesRZQS71DV1CoolingCooling capacityI

Page 5 - 1 Features

• Outdoor Units • R-410A • RZQS-DV115• Split Sky Air • Outdoor Units135 Capacity tables5 - 2 Cooling capacity tablesRZQS100DV1CoolingCooling capacityI

Page 6 - 2 Specifications

315• Split Sky Air • Outdoor Units14• Outdoor Units • R-410A • RZQS-DV15 Capacity tables5 - 2 Cooling capacity tablesRZQS125DV1CoolingCooling capacity

Page 7

• Outdoor Units • R-410A • RZQS-DV115• Split Sky Air • Outdoor Units155 Capacity tables5 - 2 Cooling capacity tablesRZQS140DV1CoolingCooling capacityI

Page 8

315• Split Sky Air • Outdoor Units16• Outdoor Units • R-410A • RZQS-DV15 Capacity tables5 - 2 Cooling capacity tablesRZQS140DV1CoolingCooling capacity

Page 9 - 3 Electrical data

• Outdoor Units • R-410A • RZQS-DV115• Split Sky Air • Outdoor Units175 Capacity tables5 - 2 Cooling capacity tables3TW31712-1RZQS71-140DV1Capacity (%

Page 10 - 4 Options

315• Split Sky Air • Outdoor Units18• Outdoor Units • R-410A • RZQS-DV15 Capacity tables5 - 3 Heating capacity tablesRZQS71DV1HeatingHeating capacityI

Page 11 - 5 Capacity tables

• Outdoor Units • R-410A • RZQS-DV115• Split Sky Air • Outdoor Units195 Capacity tables5 - 3 Heating capacity tablesRZQS100DV1HeatingHeating capacityI

Page 12

Split - Sky AirEEDEN09-100 - 01/2009Printed in Belgium by Goekint GraphicsCopyright © DaikinNaamloze VennootschapZandvoordestraat 300B-8400 Ostend, Be

Page 13

315• Split Sky Air • Outdoor Units20• Outdoor Units • R-410A • RZQS-DV15 Capacity tables5 - 3 Heating capacity tablesRZQS125DV1HeatingHeating capacity

Page 14

• Outdoor Units • R-410A • RZQS-DV115• Split Sky Air • Outdoor Units215 Capacity tables5 - 3 Heating capacity tablesRZQS140DV1HeatingHeating capacityI

Page 15

315• Split Sky Air • Outdoor Units22• Outdoor Units • R-410A • RZQS-DV15 Capacity tables5 - 3 Heating capacity tablesRZQS140DV1HeatingHeating capacity

Page 16

• Outdoor Units • R-410A • RZQS-DV116• Split Sky Air • Outdoor Units236 Dimensional drawing & centre of gravity6 - 1 Dimensional drawing3TW25144-1

Page 17 - 5 - 2 Cooling capacity tables

316• Split Sky Air • Outdoor Units24• Outdoor Units • R-410A • RZQS-DV16 Dimensional drawing & centre of gravity6 - 2 Centre of gravity4TW30469-3R

Page 18

• Outdoor Units • R-410A • RZQS-DV117• Split Sky Air • Outdoor Units257 Piping diagram3TW29165-1RZQS71-140DV1 (Pair)Indoor unitField piping J15.9 C122

Page 19

317• Split Sky Air • Outdoor Units26• Outdoor Units • R-410A • RZQS-DV17 Piping diagram3TW29165-3RZQS100,125,140DV1 (Triple)Indoor unitField piping J1

Page 20

• Outdoor Units • R-410A • RZQS-DV118• Split Sky Air • Outdoor Units278 Wiring diagram8 - 1 Wiring diagram2TW30466-1BRZQS71DV1A1P : Printed circuit bo

Page 21

319• Split Sky Air • Outdoor Units28• Outdoor Units • R-410A • RZQS-DV19 Sound data9 - 1 Sound pressure spectrum3TW30467-1Sound pressure level (dB)Oct

Page 22

• Outdoor Units • R-410A • RZQS-DV119• Split Sky Air • Outdoor Units299 Sound data9 - 1 Sound pressure spectrum3TW29167-1Sound pressure level (dB)Octa

Page 23 - 6 - 1 Dimensional drawing

technical dataSplitSky Airair conditioning systemsRZQS-DV1EEDEN09-100

Page 24 - 6 - 2 Centre of gravity

319• Split Sky Air • Outdoor Units30• Outdoor Units • R-410A • RZQS-DV19 Sound data9 - 2 Sound power spectrum3TW30467-3Sound power level (dB)Octave ba

Page 25 - 7 Piping diagram

• Outdoor Units • R-410A • RZQS-DV1110• Split Sky Air • Outdoor Units3110 Installation10 - 1 Installation method3TW26739-4Do not stack more than one u

Page 26

3111• Split Sky Air • Outdoor Units32• Outdoor Units • R-410A • RZQS-DV111 Operation rangeRZQS71-140DV13TW29063-1DNOTE1 Depending on operation and ist

Page 28 - 9 - 1 Sound pressure spectrum

• Split Sky Air • Outdoor Units4• Outdoor Units • R-410A • RZQS-DV1TABLE OF CONTENTSRZQS-DV11Features . . . . . . . . . . . . . . . . . . . . . . . .

Page 29

• Outdoor Units • R-410A • RZQS-DV111• Split Sky Air • Outdoor Units51 FeaturesOutdoor Uni Split Sky RZQS-DV1R-410A• Outdoor units for pair, twin, tr

Page 30 - 9 - 2 Sound power spectrum

312• Split Sky Air • Outdoor Units6• Outdoor Units • R-410A • RZQS-DV12 Specifications2-1 NOMINAL CAPACITY AND NOMINAL INPUT RZQS71D7V1B RZQS100D7V1B

Page 31 - 10 Installation

• Outdoor Units • R-410A • RZQS-DV112• Split Sky Air • Outdoor Units72 SpecificationsFor combination indoor units + outdoor unitsEER Nominal 2.81 2.81

Page 32 - 11 Operation range

312• Split Sky Air • Outdoor Units8• Outdoor Units • R-410A • RZQS-DV12 SpecificationsRefrigerant Type R-410ACharge kg 2.75 3.7 3.7 3.7Control Expansi

Page 33

• Outdoor Units • R-410A • RZQS-DV113• Split Sky Air • Outdoor Units93 Electrical data3D063321SYMBOLSMCA : Min. Circuit Amps (A)TOCA : Total Over Curr

Comments to this Manuals

No comments