Priority Room Setting
The Priority Room Setting requires initial programming during installation. Please consult your
retailer or dealer for assistance.
The room designated as the Priority Room takes priority in the following situations;
1. Operation Mode Priority
As the operation mode of the Priority Room takes precedence, the user can select a different
operation mode from other rooms.
<Example>
* Room A is the Priority Room in the examples.
When COOL mode is selected in Room A while operating the following modes in Room B,C and
D :
2. Priority when POWERFUL operation is used
<Example>
* Room A is the Priority Room in the examples.
The indoor units in Rooms A,B,C and D are all operating. If the unit in Room A enters
POWERFUL operation, operation capacity will be concentrated in Room A. In such a case, the
cooling (heating) efficiency of the units in Rooms B,C and D may be slightly reduced.
3. Priority when using OUTDOOR UNIT SILENT operation
<Example>
* Room A is the Priority Room in the examples.
Just by setting the unit in Room A to SILENT operation, the air conditioner starts OUTDOOR
UNIT SILENT operation.
You don’t have to set all the operated indoor units to SILENT operation.
Operation mode in Room B, C and D
Status of Room B, C and D when the unit in Room
A is in COOL mode
COOL or DRY or FAN Current operation mode maintained
HEAT
The unit enters Standby Mode. Operation resumes
when the Room A unit stops operating.
AUTO
If the unit is set to COOL mode, operation
continues. If set to HEAT mode, it enters Standby
Mode. Operation resumes when the Room A unit
stops operating.