4. Connection method to product
Basically, Transmission Monitor should be connected to the communication wires (3 wires) of indoor and
outdoor units. As for some RA products produced in and after 2001, assignment of transmission wire has
been changed from No. 2 to No.3 of the terminal block. Therefore, the connection method should be
selected from the following two methods according to the models applied.
It is recommended to measure the voltage to determine the connection method. Take Connection method 1
when the power supply voltage is impressed between connection wire 1-3, and Connection method 2 when
the power supply voltage is impressed between connection wires 1-2. However, since connection method
cannot be determined with voltage measurement when any malfunction in communication wiring or in
transmission is occurred, it is required to confirm with wiring diagrams or those in service manual.
1. Connection method 1 (Power Supply1 to 3)
When power supply 1 to 3.
Connection
wire/ No. of
product
Transmission
monitor wiring
Meaning of
wiring
1 A(Red)
Power supply
2 B(White)
Signal
(
between
connection
wire 2 to 3
)
3 C(Black)
Power supply
2. Connection method 2 (Power Supply1 to 2)
When power supply 1 to 2.
Connection
wire/ No. of
product
Transmission
monitor wiring
Meaning of
wiring
1 A(Red)
Power supply
2 C(Black)
Power supply
3 B(White)
Signal
(
between
connection
wire 2 to 3
)
Caution: Incorrect connection (incorrect wiring) may not damage the Transmission Monitor or the product
itself but may cause transmission error. The short-circuited clip of Transmission Monitor could result
in damage of the components of product. Therefore, care should be taken for the positive connection.
Indoor Unit
Outdoor Unit
Transmission
Monitor
Connection method 1(Power Supply 1 to 3)
A
B
C
1 2 3
Indoor Unit
Outdoor Unit
Transmission
Monitor
Connection method 2 (Power Supply 1 to 2)
A
B
C
1 2 3
A
Be careful for
short circuiting
caused b
y
the
Example of connection to out door unit
Example of connection to indoor unit