Is the unit operating beyond the
specified range?
Explain the specified range for
continuous operation to improve the
operating conditions.
NG
Is value of each temperature thermisto
r
close to measured value?
Replace the thermistor. (If the
malfunction is not remedied eve
n
when the thermistor is replaced,
replace the PC board.)
Does value of each temperature thermisto
r
remain within normal operating range?
Locate the causes based on the
abnormal value.
Example:
Insufficient or excessive
refrigerant amount
Dirty air filter
Dirty heat exchanger
Clogged refrigerant circuit, etc.
Probe causes other than main unit including insufficien
t
or excessive capacity, short circuit, etc.
Malfunction 7-8: Error Code “A5” (Overload/Freeze-up Protection) is
displayed
Possible
causes
Ԙ Dirty indoor unit filter or heat exchanger
ԙ Faulty thermistor
Ԛ Insufficient or excessive refrigerant amount
ԛ Clogged refrigerant circuit
Ԝ Local causes (cooling in low outside air temperature, heating in high temperature,
short circuit, etc.)
ԝ Faulty PC board
Since information may not enough with the transmission monitor to verify on some models, refer to the
operating pressure, operating current, etc. as well for diagnosis.
(Reference)
The error code “A5” (Overload/Freeze-up Protection) is detected by the indoor unit heat exchange
thermistor and outdoor unit heat exchange thermistor. Check for the reading of microcomputer with the
transmission monitor while measuring the temperature through the heat exchanger thermistors. If both
temperatures are coincided, probe real causes to actuate the overload control.