Daikin FAQ100BUV1B User Manual

Browse online or download User Manual for Split-system air conditioners Daikin FAQ100BUV1B. Split Sky Air

  • Download
  • Add to my manuals
  • Print
  • Page
    / 19
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
FAQ-BU
Wall Mounted Unit
technical data
Split
Sky Air
air conditioning systems
Page view 0
1 2 3 4 5 6 ... 18 19

Summary of Contents

Page 1 - Wall Mounted Unit

FAQ-BU Wall Mounted Unittechnical data SplitSky Airair conditioning systems

Page 2 - Split - Sky Air

5Wiring diagrams3D043881FAQ71BUV1BA1P Printed circuit boardHAP Light emitting diode (service monitor green)M1S Motor (swing flap)M1F Motor (indoor fan

Page 3 - TABLE OF CONTENTS

4D044475V1, ModelPower supply1∼50Hz220V-240VMain switchFuseFuseNOTES1 Line voltage wiringControl circuit wiring2 All wiring, components and materials

Page 4 - 2130 8qx

6Sound levels6-1Sound level dataOctave band sound pressure levelModelSound pressure levelSound power level230VMeasuring location50HzCoolingH/LHeatingH

Page 5 - Specifications

7Air flow patternsFAQ71BUV1BCooling - air velocity distributionAir flow direction: 10° (downward)FAQ71BUV1BCooling - air temperature distributionAir f

Page 6

FAQ71BUV1BHeating - air velocity distributionAir flow direction: 65°C (downward)FAQ71BUV1BHeating - air temperature distributionAir flow direction: 65

Page 7

FAQ100BUV1BCooling - air velocity distributionAir flow direction: 10° (downward)FAQ100BUV1BCooling - air temperature distributionAir flow direction: 1

Page 8 - Dimensional drawings

FAQ100BUV1BHeating - air velocity distributionAir flow direction: 65°C (downward)FAQ100BUV1BHeating - air temperature distributionAir flow direction:

Page 9 - Piping diagrams

8Accessories8-1Standard accessoriesName 1. Installation panelInsulation for fitting(for refrigerant pipe)4. Insulation tape 5. Paper pattern for insta

Page 10 - Wiring diagrams

9Control systems9-1Wired remote control6.5 x 9 (Round end slit)Cover openCover closed5 x 7 (Round end slit)HoleJ55 x 10 (Round end slit)3TW23651-2BRC1

Page 11

10Safety device settingsFAQ71-100BUV1BModel Safety devices FAQ71BUV1B FAQ100BUV1BFAQ∼BUV1BFuse −−Fan motor thermal fuse (°C) −−Fan motor thermal prote

Page 12 - Sound levels

Split - Sky AirEEDE05-1/3 • 05/2005Prepared in Belgium by Goekint GraphicsB - 8400 Ostend BelgiumSpecifications are subject to change without prior no

Page 13 - 4D039573A

TABLE OF CONTENTSFAQ-BU1 Features ... 22 Specifications...

Page 14 - 4D039574A

1Features+ Ideal for shops, restaurants or offices requiring maximum floorspace for furniture and fittings+ The 71 class has a modern casing: it is ve

Page 15 - 4D028547A

2SpecificationsNOMINAL CAPACITY and NOMINAL INPUTFor indoor units only:INDOOR UNITS FAQ71BUV1B FAQ100BUV1BNOMINAL INPUT Cooling kW 0.068 0.101Heating

Page 16 - 4D028548A

TECHNICAL SPECIFICATIONSINDOOR UNITS FAQ71BUV1B FAQ100BUV1BDIMENSIONS Unit H mm 290 360W mm 1,050 1,570D mm 230 200WEIGHT Unit kg 13 26MATERIAL Unit R

Page 17 - Accessories

ELECTRICAL SPECIFICATIONSFor indoor units only: FAQ71BUV1B FAQ100BUV1BCURRENT Nominal running currentcoolingASee chapter RR-B7, RQ-B7, RZQ-BheatingAMa

Page 18 - Control systems

3Dimensional drawingsunit (mm)50 or more30 or more(Required space)J80 holeapprox. 345approx. 475FAQ71BUV1Bapprox. 400Mounting locationapprox. 390Pipin

Page 19 - Installation

4Piping diagramsO Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipeIndoor heat exchangerField piping

Comments to this Manuals

No comments