Is outdoor unit data displayed wit
h
transmission monitor connected to
terminal board of indoor unit?
Faulty outdoor unit PC board
Faulty transmission wire
To Malfunction 7-6
Replace indoor unit PC board.
Does LED-B break blinking sometimes?
Noise entered the power supply line.
(Refer to the example of noise described i
n
Malfunction 7-1.)
Normal
Not displayed
Malfunction 7-4: Indoor Unit LED-B Off (LED-A Blinks)
Possible
causes
Ԙ Faulty transmission wiring
ԙ Faulty outdoor unit PC board
Ԛ Faulty indoor unit PC board
(Reference)
Since this malfunction relates to outdoor unit very much, diagnose together with Malfunction 7-5 and 7-6. If
the outdoor unit can be easily checked, it is recommended to check of outdoor unit LED-A first to start
diagnosing with the outdoor unit.
(Reference example) LED-B is turned off sometimes. (Other LED blinks normally.)