Daikin FT25JV1B Installation Manual Page 20

  • Download
  • Add to my manuals
  • Print
  • Page
    / 31
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 19
19
OK
YES
NG
YES
NO
NG
NO
YES
NO
OK
OFF
Blinks
Is LED-A turned off by turning
power supply back on?
Is correct power supply
voltage supplied?
Does LED-A blink right after the power
supply is turned on and goes out after that?
Does the fuse on outdoor uni
t
PC board or power supply line,
etc. has continuity?
If LED-A continues blinking after that,
normal. (Noise, etc. may have entered.
Refer to the example of noise
described in Malfunction 7-1.)
Is outdoor unit data displayed with No.2
transmission wire disconnected and transmission
monitor connected to terminal board of outdoo
r
unit?
Recheck the power supply.
Is voltage normally output fro
m
the secondary side of transformer?
Replace the transformer.
Replace the fuse.
(Probe possible causes o
f
melt down of the fuse.)
Replace the outdoor unit PC board.
Replace outdoor unit PC
board.
Malfunction 7-6: Outdoor Unit LED-A Off
Possible
causes
Ԙ Incorrect power supply voltage or faulty transmission wire
ԙ Faulty outdoor unit PC board
Ԛ Faulty indoor unit PC board
ԛ Molten fuse
Ԝ Faulty transformer
ԝ Incorrect combination of indoor and outdoor units