Daikin RXQ18P7W1BA Specifications Page 35

  • Download
  • Add to my manuals
  • Print
  • Page
    / 80
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 34
p. 35
RXYQ-P
Combination RXYQ8P7W1B
RXYQ10P7W1B
RXYQ12P7W1B
Nominal capacity cooling kW
heating kW
COP cooling
heating
Capacity range HP
Power input (nominal) cooling kW
heating kW
Max n° of indoor units to be connected
Indoor index connection minimum
maximum
Casing colour
material
Fan type
air flow rate cooling m
3
/min
(nominal at 230V)
heating m
3
/min
external static pressure (MAX) Pa
Compressor type
Operation range cooling minimum °CDB
maximum °CDB
heating minimum °CWB
maximum °CWB
Refrigerant type
charge kg
control
Maximum total refrigerant charge in the system kg
Refrigerant Oil type
charged volume l
Piping Connections liquid type
diameter (OD) mm
gas type
diameter (OD) mm
heat insulation
max. total length m
Defrost method
Defrost control
Capacity control method
Capacity control [%]
Safety devices
Power supply name
phase
frequency Hz
voltage V
Notes: Nominal cooling capacities are based on : indoor temperature : 27°CDB, 19°CWB, outdoor temperature : 35°CDB, equivalent refrigerant piping : 7.5m, level difference : 0m.
Nominal heating capacities are based on : indoor temperature : 20°CDB, outdoor temperature : 7°CDB, 6°CWB, equivalent refrigerant piping : 7.5m, level difference : 0m
Sound level of a multi system is determined by the individual outdoor unit and installation condition
The refrigerant charge of the system must be less than 100 kg. This means that in case the calculated refrigerant charge is equal to or more than 95 kg, you must divide your multiple outdoor system into smaller independent systems,
each containing less than 95 kg refrigerant charge. For factory charge, refer to the namplate of the unit.
RXYQ24P7W1B RXYQ26P7W1B RXYQ28P7W1B RXYQ30P7W1B RXYQ32P7W1B RXYQ34P7W1B RXYQ36P7W1B
3 2 1 1
1 2 3 1
2 2 3
67.2 72.8 78.4 84.0 89.4 95.0 101.0
75.0 81.5 88.0 94.5 100.0 107.0 113.0
4.02 3.94 3.84 3.77 3.60 3.56 3.49
3.97 4.20 4.13 4.09 4.05 4.02 3.99
24 26 28 30 32 34 36
16.7 18.5 20.4 22.3 24.8 26.7 28.9
18.9 19.4 21.3 23.1 24.7 26.6 28.3
39 42 45 48 52 55 58
300 325 350 375 400 425 450
780 845 910 975 1,040 1,105 1,170
Daikin White
Painted galvanised steel
Propeller Propeller Propeller Propeller Propeller Propeller Propeller
171 + 171 + 171 171 + 171 + 185 171 + 185 + 185 185 + 185 + 185 171 + 196 + 196 185 + 196 + 196 196 + 196 + 196
171 + 171 + 171 171 + 171 + 185 171 + 185 + 185 185 + 185 + 185 171 + 196 + 196 185 + 196 + 196 196 + 196 + 196
78Pa in high static pressure
Hermetically sealed scroll compressor
-5.0 -5.0 -5.0 -5.0 -5.0 -5.0 -5.0
43.0 43.0 43.0 43.0 43.0 43.0 43.0
-20.0 -20.0 -20.0 -20.0 -20.0 -20.0 -20.0
15.0 15.0 15.0 15.0 15.0 15.0 15.0
R-410A
7.7 + 7.7 + 7.7 7.7 + 7.7 + 8.4 7.7 + 8.4 + 8.4 8.6 + 8.6 + 8.6 7.7 + 8.6 + 8.6 8.4 + 8.6 + 8.6 8.6 + 8.6 + 8.6
Expansion valve (electronic type)
Less than 100 (calculated charge less than 95)
Synthetic (ether) oil
2.1 + 2.1 + 2.1 2.1 + 2.1 + 3.9 2.1 + 3.9 + 3.9 3.9 + 3.9 + 3.9 2.1 + 3.9 + 3.9 3.9 + 3.9 + 3.9 3.9 + 3.9 + 3.9
Braze connection
15.9 19.1 19.1 19.1 19.1 19.1 19.1
Braze connection
34.9 34.9 34.9 34.9 34.9 34.9 41.3
Both liquid and gas pipes
1,000 1,000 1,000 1,000 1,000 1,000 1,000
Reversed cycle
Sensor for outdoor heat exchanger temperature
Inverter controlled
~ 100 ~ 100 ~ 100 ~ 100 ~ 100 ~ 100 ~ 100
HPS, fan motor driver overload protector, overcurrent relay, inverter overload protector, PC board fuse
W1 W1 W1 W1 W1 W1 W1
3N~ 3N~ 3N~ 3N~ 3N~ 3N~ 3N~
50 50 50 50 50 50 50
400 400 400 400 400 400 400
1602UKEPCEN07-200-artwork.indd 351602UKEPCEN07-200-artwork.indd 35 1/8/07 07:15:291/8/07 07:15:29