Wiring Method (See ‘‘8. ELECTRIC WIRING WORK’’)
(3) Remove the control box lid
(4) Add remote controller 2 (slave) to the terminal block for remote controller (P
1
, P
2
) in the control
box. (There is no polarity.) (Refer to Fig. 33 and Table 4)
NOTE
1.
All transmission wiring except for the remote controller wires is polarized and must match the terminal symbol.
2. In case of group control, perform the remote controller wiring to the master unit when connecting to the
simultaneous operation system. (wiring to the slave unit is unnecessary)
3. For group control remote controller, choose the remote controller that suits the indoor unit which has the
most functions (as attached swing flap)
10. INSTALLATION OF THE DECORATION PANEL
<Read ‘‘12. TEST OPERATION’’ before making a test run without attaching the decorated panels.>
Refer to the installation manual attached to the decoration panel.
After installing the decoration panel, ensure that there is no space between the unit body and decoration
panel.
When making a test run before installation of the decoration panel, be sure to check the operation of the
swing flap after the installation.
11. FIELD SETTING
Be sure to check that the outdoor unit has been wired.
Make sure the control box lids are closed on the indoor and outdoor units.
<Field setting must be made from the remote controller and in accordance with installation conditions.>
Setting can be made by changing the “Mode No”, “FIRST CODE NO.” and “SECOND CODE NO.”.
For setting procedures and instructions, see “Field settings” provided with the remote controller.
*Settings are done in a batch for the group. To make or confirm settings for an individual unit, set the Mode
No. shown in parentheses.
Do not set numbers unless mentioned in the table.
11-1 Setting ceiling height
Select the SECOND CODE NO. that corresponds to the ceiling height “Table 5”.
(SECOND CODE NO. is factory set to “01” for a ceiling height of less than 2.7m.)
Upper part of
remote controller
Lower part of
remote controller
Insert the screwdriver
here and gently work
off the upper part of
remote controller.
S
M
S
S
M
Remote
controller
PC board
(Factory setting)
(Only one remote
controller needs
to be changed if
factory settings
have remained
untouched.)
Fig. 36
Fig. 35
Page view 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 31 32

Comments to this Manuals

No comments