Page 1 - OPERATION MANUAL

DAIKIN ROOM AIR CONDITIONEROPERATION MANUALEnglishDeutschFrançaisNederlandsEspañolItalianoPortuguesMODELSFTXS60GV1BFTXS71GV1B00_CV_3P248442-3.fm Page

Page 2 - CONTENTS

9English Checks on remote controller settings• This remote controller is common to the heat pump model and cooling only model. Use the DIP switch on t

Page 3 - Safety Precautions

10OPERATIONAUTO · DRY · COOL · HEAT · FAN OperationThe air conditioner operates with the operation mode of your choice. From the next time on, the air

Page 4 - System relocation

11English To change the airflow rate setting5. Press . • Indoor unit quiet operationWhen the airflow is set to “ ”, the noise from the indoor unit wi

Page 5 - Names of Parts

12Adjusting the Airflow DirectionYou can adjust the airflow direction to increase your comfort. To start auto swingPress .• “ ” is displayed on the

Page 6 - Outdoor Unit

13English To set the flaps or louvers at desired position • This function is effective while flaps or louvers are in auto swing mode. Press and wh

Page 7

14COMFORT AIRFLOW and INTELLIGENT EYE Operation COMFORT AIRFLOW operationThe flow of air will be in the upward direction while in COOL operation and i

Page 8 - Preparation before Operation

15English To start operationPress and select the desired mode.• Each time the is pressed a different setting option is displayed on the LCD.• By

Page 9

16COMFORT AIRFLOW and INTELLIGENT EYE OperationNOTE CAUTION Notes on COMFORT AIRFLOW operation • The flap position will change, preventing air from

Page 10 - DIP switch

17EnglishPOWERFUL OperationPOWERFUL operation quickly maximizes the cooling (heating) effect in any operation mode. You can get the maximum capacity.

Page 11 - HEAT PUMP

18OUTDOOR UNIT QUIET OperationOUTDOOR UNIT QUIET operation lowers the noise level of the outdoor unit by changing the frequency and fan speed on the o

Page 12 - 5. Press

1EnglishCONTENTSREAD BEFORE OPERATIONSafety Precautions ... 2Names of Parts ...

Page 13 - To start auto swing

19EnglishECONO OperationECONO operation is a function which enables efficient operation by limiting the maximum power consumption value. This function

Page 14 - CAUTION

20OFF TIMER OperationTimer functions are useful for automatically switching the air conditioner on or off at night or in the morning. You can also use

Page 15 - INTELLIGENT EYE Operation

21EnglishON TIMER Operation To use ON TIMER operation • Check that the clock is correct. If not, set the clock to the present time. (page 8.) 1. Press

Page 16 - COMFORT

22WEEKLY TIMER OperationUp to 4 timer settings can be saved for each day of the week. It is convenient if the WEEKLY TIMER is set according to the fam

Page 17

23English To use WEEKLY TIMER operation • Make sure the day of the week and time are set. If not, set the day of the week and time. (page 8.) 1. Press

Page 18 - POWERFUL Operation

24WEEKLY TIMER Operation6. Press to select the desired time.• The time can be set between 0:00 and 23:50 in 10 minute intervals. • To return to the

Page 19 - OUTDOOR UNIT QUIET Operation

25EnglishNOTE Notes on WEEKLY TIMER operation• Do not forget to set the clock on the remote control first.• The day of the week, ON/OFF TIMER mode,

Page 20 - ECONO Operation

26WEEKLY TIMER Operation • A reservation made once can be copied another day of the week. The whole reservation of the selected day of the week will b

Page 21 - OFF TIMER Operation

27English5. Press . • The reservation will be copied to the selected day of the week. The whole reservation of the selected day of the week will be c

Page 22 - ON TIMER Operation

28WEEKLY TIMER Operation Confirming a reservation • The reservation can be confirmed.1. Press .• The day of the week and the reservation number of th

Page 23 - WEEKLY TIMER Operation

2READ BEFORE OPERATIONSafety Precautions• Keep this manual where the operator can easily find them.• Read the precautions in this manual carefully bef

Page 24 - ON TIMER OFF TIMER

29English To delete reservations • Refer to setting mode. (page 23.) When selecting desired mode at step 4 in setting mode, select “blank”. The reserv

Page 25

30Note for Multi SystemThis system has one outdoor unit connected to multiple indoor units. Selecting the operation mode1. With the priority room set

Page 26 - Setting Displays

31English OUTDOOR UNIT QUIET operation (page 18.)1. With the priority room setting present but inactive or not present.When using the OUTDOOR UNIT QUI

Page 27

32CARECare and Cleaning Indoor unit, outdoor unit and remote controller 1. Wipe them with dry soft cloth. Front panel 1. Open the front panel. • Hold

Page 28

33English 1. Pull out the air filters. • Open the front panel.• Push a little upwards the tab at the center of each air filter, then pull it down. 2.

Page 29

34Care and Cleaning3-2 Titanium apatite photocatalytic air-purifying filter The titanium apatite photocatalytic air-purifying filter can be renewed by

Page 30 - To delete reservations

35EnglishCheck Before a long idle period1. Operate the FAN only for several hours on a fine day to dry out the inside.• Press and select FAN operat

Page 31 - Note for Multi System

36TROUBLESHOOTINGTroubleshooting• Troubleshooting measures are classified into the following two types on a remedial basis. Take an appropriate measur

Page 32

37EnglishThe outdoor unit emits water or steam. In HEAT operation • The frost on the outdoor unit melts into water or steam when the air conditioner

Page 33 - Care and Cleaning

38TroubleshootingOperation stopped suddenly. (OPERATION lamp is on.)• For system protection, the air conditioner may stop operating on a sudden large

Page 34

3English• Do not block air inlets nor outlets. Impaired airflow may result in insufficient performance or trouble. • Do not sit or place objects on th

Page 35

39EnglishThe ON/OFF TIMER does not operate according to the settings.• Check if the ON/OFF TIMER and the WEEKLY TIMER are set to the same time. Change

Page 36 - Before a long idle period

40TroubleshootingWARNING When an abnormality (such as a burning smell) occurs, stop operation and turn the breaker off.Continued operation in an abno

Page 37 - Troubleshooting

41English Fault diagnosis by remote controller In the ARC452A series, the temperature display sections on the main unit indicate corresponding codes.1

Page 38

42TroubleshootingLED ON OUTDOOR UNIT PCB 3MXS, 3MKS, 4MXS, 4MKS, 5MXS, 5MKS series NOTE 1. Turn the power off and then on again. If the LED displ

Page 39

(0911)HT3P248442-3M08B300Two-dimensional bar code is a code for manufacturing.00_CV_3P248442-3.fm Page 2 Tuesday, September 8, 2009 1:14 PM

Page 40

4Names of Parts Indoor Unit 1716131514134 5911 1082612 701_EN_3P248442-3.fm Page 4 Tuesday, September 8, 2009 1:54 PM

Page 41

5English Outdoor Unit Indoor Unit 1. Air filter2. Titanium apatite photocatalytic air-purifying filter:• These filters are attached to the inside of

Page 42

6Names of Parts Remote Controller 1. Signal transmitter:• It sends signals to the indoor unit.2. Display (LCD):• It displays the current settings. (In

Page 43

7EnglishPreparation before Operation To set the batteries 1. Slide the front cover to take it off.2. Set 2 dry batteries AAA.LR03 (alkaline).3. Set th

Page 44 - 3P248442-3

8Preparation before Operation To set the clock 1. Press .• “ ” is displayed.• “ ” and “ ” blinks.2. Press to set the current day of the week.3. Pre