EDUS 39 - 900A - F11_aAMERICASFXMQ-MCeiling Mounted Duct Unit
EDUS39-900A-F11_a Capacity TablesFXMQ-M 97.2 Heating CapacityFXMQ72MVJUFXMQ96MVJUTC = Total capacity ; MBhHeating capacityOutdoorIndoor (FDB)62 65 68
Fan Performances EDUS39-900A-F11_a10 FXMQ-M8. Fan PerformancesFXMQ72MVJUNotes:1. The remote controller can be used to switch between “high” and “low”.
EDUS39-900A-F11_a Fan PerformancesFXMQ-M 11FXMQ96MVJUNotes:1. The remote controller can be used to switch between “high” and “low”.2. The air flow is
Sound Levels (Reference) EDUS39-900A-F11_a12 FXMQ-M9. Sound Levels (Reference)9.1 Overall9.2 Octave Band Level208V-230V, 60Hz Location of microphoneN
EDUS39-900A-F11_a Center of GravityFXMQ-M 1310.Center of Gravity4D065654
Installation EDUS39-900A-F11_a14 FXMQ-M11.Installation1. SAFETY CONSIDERATIONSRead these “SAFETY CONSIDERATIONS for Installation” carefully before ins
EDUS39-900A-F11_a InstallationFXMQ-M 15• Do not change the setting of the protection devices. If the pressure switch, thermal switch, or other protec-
Installation EDUS39-900A-F11_a16 FXMQ-M2. BEFORE INSTALLATION•When moving the unit while removing it from the carton box, be sure to lift it by holdin
EDUS39-900A-F11_a InstallationFXMQ-M 17b. Items to be checked at time of deliveryAlso review the “SAFETY CONSIDERATIONS”c. Points for explanation abou
Installation EDUS39-900A-F11_a18 FXMQ-M(3) Install suspension bolts.(Use bolts of 3/8in. diameter.)• Install the equipment where supporting structures
EDUS39-900A-F11_aFXMQ-M 1FXMQ-MCeiling Mounted Duct Unit1. External Appearance...
EDUS39-900A-F11_a InstallationFXMQ-M 19NOTEThe flare nuts used must be those included with the main body.CAUTIONOver-tightening may damage the flare a
Installation EDUS39-900A-F11_a20 FXMQ-M7. DRAIN PIPING WORKRig the drain pipe as shown below and take measures against condensation. Improperly rigg
EDUS39-900A-F11_a InstallationFXMQ-M 218-3 SPECIFICATIONS FOR FIELD SUPPLIED FUSES AND WIRE NOTE1. Allowable length of transmission wiring between ind
Installation EDUS39-900A-F11_a22 FXMQ-M2. Tightening torque for the terminal screws.• Use the correct screwdriver for tightening the terminal screws.
EDUS39-900A-F11_a InstallationFXMQ-M 239-3CONTROL BY 2 REMOTE CONTROLLERS (Controlling 1 indoor unit by 2 remote control-lers)• When using 2 remote co
Installation EDUS39-900A-F11_a24 FXMQ-M10. FIELD SETTINGMake sure the terminal box lids are closed on the indoor and outdoor units.Field setting must
EDUS39-900A-F11_a AccessoriesFXMQ-M 2512.AccessoriesStandard Accessories3P086156-13YOptional Accessories (For Unit)3D065676Optional Accessories (For C
Accessories EDUS39-900A-F11_a26 FXMQ-M
1645 Wallace Drive, Suite 110Carrollton, [email protected]_aPrinted in U.S.A. 08/10 AK·FS.KAMERICAS August 2010
External Appearance EDUS39-900A-F11_a2 FXMQ-M1. External AppearanceFXMQ72·96MVJU
EDUS39-900A-F11_a SpecificationsFXMQ-M 32. SpecificationsCeiling Mounted Duct UnitNotes: 1 Nominal cooling capacities are based on the following cond
Dimensions EDUS39-900A-F11_a4 FXMQ-M3. DimensionsFXMQ72MVJUFXMQ96MVJUC : 3D065655
EDUS39-900A-F11_a Piping DiagramsFXMQ-M 54. Piping DiagramsR1T : Thermistor for suction air temperatureR2T : Thermistor for liquid line temperatureR3T
Wiring Diagrams EDUS39-900A-F11_a6 FXMQ-M5. Wiring DiagramsFXMQ72/96MVJU3D065414C
EDUS39-900A-F11_a Electric CharacteristicsFXMQ-M 76. Electric CharacteristicsNOTES:1. Voltage range: Units are suitable for use on electrical systems
Capacity Tables EDUS39-900A-F11_a8 FXMQ-M7. Capacity Tables7.1 Cooling CapacityFXMQ72MVJUFXMQ96MVJUTC = Total capacity ; MBhSHC = Sensible heat capac