Split - Sky Air
®
• Outdoor Unit
31
Outdoor Unit • Pair application • RXS-J
7 Piping diagrams
7 - 1 Piping Diagrams
RXS42J2V1B
3D059590B
OUTDOOR UNIT
Outdoor temperature thermistor
Heat exchanger
Muffl er with
lter
Muffl er with
lter
Motor
operated
valve
Muffl er with
lter
12.7 CuT
9.5 CuT
6.4 CuT Ø 4.0 x ID. 2.0 CuT
7.9 CuT
9.5 CuT
Propeller fan
7.9 CuT
7.9 CuT
4.8 CuT
4.8 CuT
6.4 CuT 6.4 CuT
9.5 CuT
Liquid stop
valve
Gas stop
valve
Field piping
(6.4 CuT)
Field piping
(9.5 CuT)
9.5 CuT 9.5 CuT
Muffl er
Muffl er
Compressor
Refrigerant fl ow
Cooling
Heating
Discharge pipe
thermistor
Four way valve
on: heating
Heat exchanger
thermistor
Accumulator
7.9 CuT
RXS50J2V1B
3D051637S
OUTDOOR UNIT
Outdoor air temperature
thermistor
Heat exchanger
Muffl er with
lter
Motor
operated
valve
Filter
Reciever
6.4 CuT6.4 CuT6.4 CuT
Propeller fan
7.9 CuT
7.9 CuT
4.0 CuT
4.0 CuT
7.9 CuT
4.0 CuT
4.0 CuT
7.9 CuT
7.9 CuT
7.9 CuT
7.9 CuT12.7 CuT
7.9 CuT
7.9 CuT
7.9 CuT
6.4 CuT
6.4 CuT
12.7 CuT
9.5 CuT12.7 CuT
12.7 CuT
9.5 CuT
7.9 CuT
7.9 CuT
7.9 CuT
12.7 CuT
Refrigerant fl ow
Cooling
Heating
Liquid stop
valve
Gas stop valve
with service port
Field piping
(6.4 CuT)
Field piping
(12.7 CuT)
Muffl er
Muffl er
Muffl er
Compressor
Discharge pipe
thermistor
Four way valve
on: heating
Capillary tube 2
Capillary tube 3
Capillary tube 4
Capillary tube 1
Heat exchanger
thermistor