Page view 7
13
14
600 x 600 Ceiling-mounted cassette type
600 x 600 Ceiling-mounted cassette type
2.5 kW class
FFQ25BV1B
3.5 kW class
FFQ35BV1B
5.0 kW class
FFQ50BV1B
6.0 kW class
FFQ60BV1B
The ideal air conditioner for installation inside
narrow false ceilings—with only the smooth and
simply finished decorative panel visible after
installation. The compact dimensions are suitable
even for the light commercial market as well as for
the living rooms with false ceilings found in multi-
storey condominiums.
Compact dimensions suitable for the light commercial market
Design flexibility
Designed to fit 600 mm wide ceiling grids perfectly
Quiet sound levels of only 24.5 dB (A)
Multi-flow system offers a selection of air discharge
patterns that suit all areas.
Comfort and quietness
600 x 600
Option
Option
Signal receiver unit
Note: Remote controller
cables not included.
Cables should be
obtained locally.
Note: Wireless remote
controllers and signal
receiver units are sold
as a set.
Even for modules other than 600 x 600, no inspection
opening is required. Maintenance can be performed after
simply removing the grille, because the switchbox is built
into the unit.
T-bar grid does not need to be cut.
575 mm
575 mm
700 mm
700 mm
286
mm
Compact
decorative panel
T-bar
600 mm
600 mm
Ceiling panel
Spiral hub cover
At low fan speeds, the 2.5 kW
model produces sound of only
24.5 dB (A), and even the 6.0
kW model as low as 32 dB
(A). This is due to a new
spiral hub cover that reduces
internal airflow resistance.
4-way flow
1 pattern
3-way flow
4 patterns
2-way flow
1 pattern
" " denotes piping direction. " " denotes sealing member for air discharge
outlet (option).
Note: For 3-way or 2-way flow installation, the sealing member for air
discharge outlet (option) must be used to close off the unused outlet(s).
Low draft performance is designed for your comfort.
Horizontal Flow
0°
0°
Less draught
FFQ25B
29.5/24.5 dB (A)
FFQ35B
32/25 dB (A)
FFQ50B
36/27 dB (A)
FFQ60B
41/32 dB (A)
(H/L)
Settable to 5 different levels
between
0° and 35°
Settable to 5 different levels
between 0° and 60°
Settable to 5 different levels
between 25° and 60°
Auto-swing
between 0° and 35°
Auto-swing
between 0° and 60°
Auto-swing
between 25° and 60°
Draft
prevention
setting
(Set on site)
(Set on site)
Standard
setting
Setting to
prevent
soiling of
ceiling
Conditioned air is distributed
evenly by Auto-swing
operation.
Adjustable air blow angle to
suit all room conditions.
AUTO-SWING
0°
0°
0°
25°
60°
60°
0°
35°
25°
60°
35°
60°
5 direction
Note: Angles shown above are provided as a guide. They may differ depending on the installation site.