Daikin Super Multi Plus D-Series User Manual Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
23
24
Outdoor unit
Specifications
Outdoor unit
Model name
Power supply
Capacity (rated)
Total indoor unit capacity
Number of indoor units to be connected
Number of BP to be connected
Casing colour
Compressor
Airflow rates (H)
Refrigerant
Refrigerant oil
Sound levels
Dimensions (H x W x D)
Machine weight
Operation range
Number of wiring connections
Piping connections
Max. interunit
piping length
Necessity of additional charge
Max. height difference
Type
Motor output
Type
Charge
Model
Charge
Liquid (flare)
Gas (brazing)
Drain
Total main piping and
branch piping
Total main piping
Total branch piping
Max. length for each
kW
kW
kW
kg
dB (A)
mm
kg
˚CDB
mm
mm
mm
m
m
m
m
kg/m
m
m
Note: * Refrigerant charge is required. (Chargeless piping length 0 m)
Formula for calculation charge: R (kg)
R = Total length (m) of liquid pipe size at ø9.5 x 0.054 + Total length (m) of liquid piping size at ø6.4 x 0.022
RMKS112EVM
11.2
5.5 to 14.5
5
2.5
52
115
60
RMKS140EVM
14.0
7.0 to 18.2
7
3
Ivory white
Hermetically sealed scroll type
3.0
106 (3,742)
R-410A
4.0
DAPHNE FVC68D
1.5
53
1,345 x 900 x 320
125
-5 to 46
ø9.5
ø19.1
ø18.0
135
55
80
15
Necessary*
RMKS160EVM
15.5
8.0 to 20.8
8
3.5
54
145
90
Between indoor or BP unit and outdoor unit: 30
Between indoor and BP unit: 15
1 phase, 220-230 V, 50/60 Hz
m
3
/min (cfm)
3 for power supply (including earth wiring), 2 for interunit wiring (outdoor unit-BP)
Cooling only
Measurement conditions
1. Data is based on the following conditions: indoor temp. 27˚CDB, 19˚CWB; outdoor temp. 35˚CDB.
2. Sound levels are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.
600 x 600 Ceiling-mounted cassette type
Indoor unit
Model name
Power supply
Airflow rates (H)
Sound levels (H/L)*
Fan speed
Temperature control
Unit dimensions (H x W x D)
Machine weight
Piping connections
Heat insulation
Liquid (flare)
Gas (flare)
Drain
dB (A)
mm
kg
mm
mm
mm
Model
Colour
Dimensions (H x W x D)
Weight
mm
kg
Panel
(option)
55 x 700 x 700
FFQ35BV1B
10.0 (353)
32/25
FFQ50BV1B
12.0 (424)
36/27
FFQ60BV1B
15.0 (530)
41/32
FFQ25BV1B
9.0 (318)
29.5/24.5
White
286 x 575 x 575
17.5
ø6.4
VP20 (External Dia. 26/Internal Dia. 20)
BYFQ60B8W1
2.7
Cooling only
2 steps
Microcomputer control
Both liquid and gas pipes
1 phase, 220-240 V, 50 Hz
ø9.5 ø12.7
600 x 600
Ceiling-mounted cassette type
Model name
Power supply
Airflow rates (H)
Sound levels (H/L)*
Fan speed
Temperature control
Unit dimensions (H x W x D)
Machine weight
Piping connections
Heat insulation
Liquid (flare)
Gas (flare)
Drain
mm
kg
FCQ50BVE
15.0 (530)
ø6.4
FCQ60BVE FCQ71BVE
dB (A)
mm
kg
mm
mm
mm
Note: * For 220 V operation.
33/29
ø12.7
FCQ35BVE
14.0 (494)
ø9.5
ø9.5
ø15.9
35/30
Colour
Dimensions (H x W x D)
Weight
Panel
(option)
Model
White
40 x 950 x 950
5
Cooling only
Both liquid and gas pipes
BYC125K-W1
I.D ø25 x O.D ø32
2 steps
Microcomputer control
1 phase, 220-240 V/220 V, 50/60 Hz
230 x 840 x 840
24
19.0 (671)
m
3
/min (cfm)
m
3
/min (cfm)
Note: * Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
Page view 12
1 2 ... 8 9 10 11 12 13 14 15 16

Comments to this Manuals

No comments