WARNINGS
Always use a licensed installer or contractor to install this product. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a licensed contractor to install those parts and accessories. Use of unauthorized parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.
Read the User’s Manual carefully before using this product. The User’s Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
For any inquiries, contact your local Daikin sales office.
©2008 Daikin Industries, Limited.
Daikin,
®
AC
and Absolute Comfort
are pending trademarks or registered trademarks of Daikin Industries, Limited. All rights reserved.
The air conditioners manufactured
by Daikin Industries have received
ISO 9000 series certification for
quality assurance.
All Daikin Industries locations and
subsidiaries in Japan have received
environmental management system
standard ISO14001 certification.
About ISO 14001
ISO 14001 is the standard defined by the International
Organization for Standardization (ISO) relating to
environmental management systems. Our group has
been acknowledged by an internationally accredited
compliance organization as having an appropriate
program of environmental protection procedures and
activities to meet the requirements of ISO 14001.
Daikin Industries, Ltd.
Domestic Group
Certificate Number: EC99J2044
Certificate Numbers:
(ISO9001) JMI-0107 (ISO9002)JQA-1452
JQA-1452
Indoor Units — Slim Duct Built-In Units
Model FDXS09DVJU FDXS12DVJU
Refrigerant R-410A R-410A
Rated Capacity* (Btu/h) nom. 9kBtu/h Class 12kBtu/h Class
Moisture Removal Pt/h 2.5 4
Airflow-Dry and Wet (cfm) H/M/L 305-280-260 305-280-260
Sound Pressure-Cooling dB(A) H/M/L 35/33/31 35/33/31
Sound Pressure-Heating dB(A) H/M/L 35/33/31 35/33/31
Condensate Drain Connection (in.) O.D. 1-1/32 1-1/32
Dimensions (in.) H x W x D 7 7/8 x 27 9/16 x 24 7/16
Weight (lbs.) 47 47
Wireless Remote Controller (standard) ARC433A63 ARC433A63
Indoor Units — Wall Mounted Units
Model CTXS09GVJU CTXS12GVJU FTXS15DVJU FTXS18DVJU
Cooling Heating Cooling Heating Cooling Heating Cooling Heating
Refrigerant R-410A R-410A R-410A R-410A
Front Panel Color Off-White Off-White Off-White Off-White
Rated Capacity* 9kBtu/h Class 12kBtu/h Class 15kBtu/h Class 18kBtu/h Class
Moisture Removal (Pt/h) n/a n/a 3.4 4.3
Airflow-Cooling (cfm) H/M/L 388/335/283 400/357/314 388/335/283 400/357/314 519/436/353 515/459/402 549/476/402 609/529/448
Sound Pressure-Cooling dB(A) H/M/L 44/40/35 44/39/34 45/41/36 45/40/35 45/41/36 44/40/35 45/41/36 44/40/35
Condensate Drain Connection (in.) O.D. 11/16 11/16 11/16 11/16
Dimensions (in.) H x W x D 11-7/16x31-5/16x9-3/8 11-7/16x41-5/16x9-3/8
Weight (lbs.) 29 29 38 38
Wireless Remote Controller (standard) ARC433A53 ARC433A53 ARC433A53 ARC433A53
Outdoor Units
Model 2MXS18GVJU 4MXS32GVJU
Capacity* 18,000 Btu class 32,000 Btu class
Casing Color Ivory White Ivory White
Power Source 1ph 208-230V 60Hz 1ph 208-230V 60Hz
Max. Fuse Size Amps 20 20
Starting Current (208/230V) Amps 9.1/8.3 15.3/13.8
Compressor Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Compressor Motor Output W 1,380 1,920
Power Consumption-Cooling W Refer to combinations table in the Engineering Data book.
Power Consumption-Heating W Refer to combinations table in the Engineering Data book.
Operating Current-Heating A Refer to combinations table in the Engineering Data book.
Operating Current-Heating A Refer to combinations table in the Engineering Data book.
Sound Pressure Level (Cooling/Heating) dB(A) 50/51 52/54
Dimensions H X W X D 28-15/16X32-1/2X11-13/16 30-5/16X35-7/16X12-5/8
Weight lbs. 139 168
Operating Range-Cooling (outdoor-db) °F 14-115 14-115
Operating Range-Heating (outdoor-db) °F 5-60 5-60
Pipe Connections-Liquid (flare type) in. 1/4x2 1/4x4
Pipe Connections-Gas (flare type) in. 3/8x2 3/8x1, 1/2x1, 5/8x2
Refrigerant Type R-410A R-410A
Refrigerant Charge lbs. 5.73 6.83
Max. Piping Length ft. 164 (for Total of Each Room) 230 (for Total of Each Room)
82 (for One Room) 82 (for One Room)
Piping Length (no add’l refrigerant) ft. 98.4 131.6
Amount of Additional Charge oz/ft 0.22 0.22
Max. Installation Height Difference ft.
(btwn Indoor Unit & Outdoor Unit) 49.2 49.2
ft.
(btwn Indoor Units) 24.6 24.6
Energy efficiency
up to SEER 19.5
and HSPF 9.6