Installation & Maintenance Data
IM 613-2
©2000 AAF-HermanNelson
Used with AAF-HermanNelson Models AVS, AVV, AVR, AHF,
AHV, AHR, AED, AEQ, AZS, AZQ, AZR, ARQ, ERQ
MicroTech
®
Unit Ventilator Controller
HermanNelson
®
J6 J7 J8 J9
LED RELAY OUT AUX OUT STATUS POWER PWR
G0 H12345678 V910 G 24V
123 123456 R543210 GSGSGSGSGSGSGSGS GS1S0
COMMB COMM A DIGITAL INPUT IN 13 IN 12 IN 7 IN 6 IN 5 IN 4 IN 3 IN 2 IN 1. 0
J1 J2 J3 J4 J5
MicroTech
®
325 Controller
This devise complies with Part 15 of the FCC rules.
Operation is subject to the following 2 conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including
interference that may cause undesired operation.
C
®
File E159169
Model 325
Part No. 107627201
J1
J2
J3
J4
J5
COOLING SETPOINT IS
FACTORY SET 6°F ABOVE
HEATING SETPOINT
HI LO
NETWORK
ADDRESS
% °F °F
MINIMUM OA UNOCCUPIED HEATING SETPOINT
POSITION OFFSET
30
40
5020
10
75
0
100
0
20
10
155
70
65
75
60
80
J6 J7 J8 STATUS POWER J9
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Page view 0
1 2 3 4 5 6 ... 31 32

Summary of Contents

Page 1 - Unit Ventilator Controller

Group: Unit VentilatorPart No.: 106102102Date: May 2000Installation & Maintenance DataIM 613-2©2000 AAF-HermanNelsonUsed with AAF-HermanNelson Mo

Page 2 - Table of Contents

IM 613 / Page 10 (Rev. 5/00)UV 1 S 2 BUnit VentilatorProgram NumberUnit TypeS = Stand-alone, Open ProtocolM = Master/SlaveN = MicroTech NetworkSoftwar

Page 3 - Introduction

Certified DrawingIM 613 / Page 11 (Rev. 5/00)The following commissioning procedures pertain to unit ventila-tors equipped with the MicroTech Unit Vent

Page 4 - Component Data

IM 613 / Page 12 (Rev. 5/00)4. Check that the conductors have been terminated at the unitand the wall sensor package in accordance with the fieldwirin

Page 5

Certified DrawingIM 613 / Page 13 (Rev. 5/00)Following are UVC start-up procedures for each communicationtype. The start-up procedure must be performe

Page 6 - Standard Control Features

IM 613 / Page 14 (Rev. 5/00)• Slave units will communicate as expected when your PC isconnected to Port-A, simply make sure you use the correctaddress

Page 7

Certified DrawingIM 613 / Page 15 (Rev. 5/00)properly. Do this by switching these devices and observingthe status LED.5. Check for proper voltage leve

Page 8 - Communication Type

IM 613 / Page 16 (Rev. 5/00)be easier to detect any wiring problems that may exist in thecommunications trunk.Communications Cable CheckPerform this c

Page 9

Certified DrawingIM 613 / Page 17 (Rev. 5/00)switch to either desired speed, wait 5 minutes until calibra-tion is complete.4. Check the status LED.The

Page 10 - Software ID

IM 613 / Page 18 (Rev. 5/00)Status LEDAlarm DescriptionUnit Ventilator ModelBlinks(Fault)Trigger Factory Setting Fault Reset(Priority ` (Clear) AED A

Page 11 - Pre-Start

Certified DrawingIM 613 / Page 19 (Rev. 5/00)The low DX coil temperature switch (T4) is wired in series withthe compressor relay output (RO-2) and the

Page 12 - Setpoint Initialization

IM 613 / Page 2 (Rev. 5/00)Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3General Description . . . . . . . . . .

Page 13 - Start-Up

IM 613 / Page 20 (Rev. 5/00)PC ConnectionA personal computer (PC) equipped with the appropriateMonitor software may be directly connected to any UVC.T

Page 14 - IM 613 / Page 14 (Rev. 5/00)

Certified DrawingIM 613 / Page 21 (Rev. 5/00)Comm. Port Terminal Connection1 Jumped to terminal 22 Jumped to terminal 13 Transmit4 Not used5

Page 15 - Certified Drawing

IM 613 / Page 22 (Rev. 5/00)Figure 5. Relay Output Wiring ExampleFigure 4a. Auxiliary Output Wiring ExampleAO-10AO-V+29vdc @ 30mARelay Coil (wiring by

Page 16 - IM 613 / Page 16 (Rev. 5/00)

Certified DrawingIM 613 / Page 23 (Rev. 5/00)ConnectionSoftwareComponent DescriptionModelIN0 AllTenant override or remote spt. adjust orboth (optio

Page 17 - Diagnostics & Service

IM 613 / Page 24 (Rev. 5/00)SoftwareConnectionModelComponent DescriptionIN0 AllTenant override or remote spt. adjust orboth (optional)IN1 All Room tem

Page 18

Certified DrawingIM 613 / Page 25 (Rev. 5/00)Table 17. Inputs and Outputs for Program UV7***Units (Models AV/AH)Table 16. Inputs and Outputs for Progr

Page 19

IM 613 / Page 26 (Rev. 5/00)Test ProceduresThis section contains troubleshooting procedures for thefollowing:• Microprocessor problems• Power supply p

Page 20 - Service Information

Certified DrawingIM 613 / Page 27 (Rev. 5/00)If the measured resistance and temperature do not match,either there is a wiring problem or the sensor is

Page 21

IM 613 / Page 28 (Rev. 5/00)UVC ReplacementData relating to the unit ventilator configuration and actuatorcharacteristics are stored at the factory wh

Page 22 - Units (Models AE or AV/AH)

Certified DrawingIM 613 / Page 29 (Rev. 5/00)Valve And Damper Actuator CalibrationProceduresPoints to keep in mind about actuator calibration.Actuator

Page 23

Certified DrawingIM 613 / Page 3 (Rev. 5/00)This manual provides information pertaining to theMicroTech Unit Ventilator Controller (UVC) as applied in

Page 24 - Units (Models AV/AH) (2 pipe)

IM 613 / Page 30 (Rev. 5/00)4. On the Read/Write screen, in the Operation box selectthe Monitor radio button by clicking on it. In the Displaybox sele

Page 25

Certified DrawingIM 613 / Page 31 (Rev. 5/00)9. Watch memory location 0507 change, when this value stopschanging, the OA damper should be fully opened

Page 26 - Test Procedures

AAF–HermanNelson4900 Technology Park Boulevard, Auburn, New York 13021-9030 USA (315) 253-2771Printed on recycled paper containing at least 10% post-c

Page 27

IM 613 / Page 4 (Rev. 5/00)J6 J7 J8 J9LED RELAY OUT AUX OUT STATUS POWER PWRG0 H12345678 V910 G 24V123 123456 R543210 GSGSGSGSGSGSGSGS GS1S0COMMB

Page 28 - UVC Replacement

Certified DrawingIM 613 / Page 5 (Rev. 5/00)Status LED State IndicationOn Continually Occupied ModeOn 1⁄2 sec./ Off 51⁄2 sec. Unoccupied ModeOn 51⁄2 s

Page 29

IM 613 / Page 6 (Rev. 5/00)ActuatorsThe UVC uses hydraulic, spring return, floating control actuatorswith position feedback for valve and damper modul

Page 30 - IM 613 / Page 30 (Rev. 5/00)

Certified DrawingIM 613 / Page 7 (Rev. 5/00)Compressor Short-Cycle ProtectionAll compressor-equipped unit ventilator models (self-containedor split sy

Page 31

IM 613 / Page 8 (Rev. 5/00)Sensor DiagnosticsIf a temperature sensor’s value is out of range, the UVC willdetect it and take the appropriate action. E

Page 32 - HermanNelson

Certified DrawingIM 613 / Page 9 (Rev. 5/00)• Day-night changeover scheduling• Heating and cooling setpoint adjustment• Minimum OA damper position set

Comments to this Manuals

No comments