Daikin ENVi Installation Manual

Browse online or download Installation Manual for Thermostats Daikin ENVi. Daikin ENVi Installation manual User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Installation Manual

Daikin ENVi Thermostat Installation Manual

Page 2 - SAFETY CONSIDERATIONS

SpecicationsThermostat SpecicationsTemperature Heat Set Point Range 45 to 80 °F (7 to 26.5 °C)Cool Set Point Range 65 to 95 °F (18.5 to 35 °C)Disp

Page 3 - CONTENTS

Wiring RequirementsThe Daikin ENVi thermostat uses 4-wire low-voltage cable to connect to the Daikin Power and Communication Adapter (DPCA) which in t

Page 4

Step 2. Position and Wire the DPCAThe Daikin Power and Communication Adapter (DPCA) provides an interface between the thermostat and Indoor Unit. To i

Page 5 - GETTING STARTED

DPCA Wiring ConnectorsStep 2. Position and Wire the DPCAThe Daikin Power and Communication Adapter (DPCA) provides an interface between the thermostat

Page 6 - Package Contents

Step 3. Install the Daikin ENVi ThermostatThe ideal location for the thermostat is approximately 5 ft (1.5 m) above oor level in the main living area

Page 7 - Before You Begin

4. Move the backplate out of the way and make holes where indicated in the previous step. The mounting holes can accommodate a #6 pan-head screw. It i

Page 8 - FCC Compliance Statement

Step 4. Connect the Thermostat WiringUse the eld-supplied 4-wire low-voltage cable to connect the thermostat to the DPCA. To connect the thermostat

Page 9

Step 5. Mount the DPCAAfter you make the necessary wiring connections, mount the DPCA by using the adhesive sticker or mounting screws as needed.Step

Page 10 - Specications

NAVIGATING THE MENUSThe Daikin ENVi thermostat has an easy-to-read color screen that displays all the information you need to congure the thermostat.

Page 11 - INSTALLING THE THERMOSTAT KIT

MENU Pressing MENU displays a list of all available options. If a menu is currently displayed, pressing MENU will cancel any unsaved changes and re

Page 12 - Power Cable

SAFETY CONSIDERATIONS Read these SAFETY CONSIDERATIONS for Installation carefully before installing the Daikin ENVi thermostat kit. After completing t

Page 13

CONFIGURING THE DAIKIN ENVi THERMOSTATThe rst step after installing the Daikin ENVi thermostat is to congure the thermostat settings for the Indoor

Page 14

Installation SettingsThe Installation Settings let you congure the equipment connected to the Daikin ENVi thermostat.Allow Auto Heat/CoolEnabling thi

Page 15 - AUXRCD+D

damage to the compressor. You can also set this value to determine when you want the auxiliary heat (if installed) to engage to help meet the set temp

Page 16

in longer cycle times. The temperature range is adjustable from 0.5 to 3 °F (0.3 to 1.7 °C) in 0.5°F (0.3°C) increments. The default oset is 0.5°F (0

Page 17 - Step 5. Mount the DPCA

reached). Options are Auto (default) and 1 to 10 °F (0.6 to 5.6°C). Only visible if Indoor Unit supports heat and an auxiliary heat source is also

Page 18 - NAVIGATING THE MENUS

Above this level, the auxiliary heat will not be activated. The temperature is adjustable from 0 to 80 °F (-17.8 to 26.5 °C) in increments of 0.5°F (0

Page 19 - On-Screen Keyboard

Tstat Temp CorrectionLets you program an oset between the real temperature at the thermostat and the displayed temperature. If you nd that the tempe

Page 20 - Preferences

Reset Contractor Info Resets any information about the Contractor who installed the Daikin ENVi thermostat.Rebooting the Daikin ENVi thermostatYo

Page 21 - Congure the devices

CONFIGURING REMINDERS AND ALERTSThe Daikin ENVi thermostat can generate periodic maintenance reminders that help the homeowner know when to perform pe

Page 22

Low Temp Limit Sets the temperature at which the thermostat will generate a Low Temperature Limit alert. The range can be: Disabled – No alert will

Page 23

CONTENTSGETTING STARTED 1Welcome 1Contractor Thermostat Registration 1Package Contents 2Before You Begin 3Daikin System Compatibility 4Approvals

Page 24 - Aux Heat Settings

List of AlertsBelow is a complete list of alerts. Depending on your conguration, some of these may not apply.Low Temp Limit Temperature in the home i

Page 25 - Force System O

ONE-YEAR LIMITED WARRANTYDaikin AC (Americas), Inc., (“Daikin AC”) warrants that for a period of one (1) year from the date of purchase by the end-use

Page 26 - Select the desired reset

The limited warranty is for repair or replacement of parts or Product only. Except to that limited extent, Daikin AC will not under any circumstances

Page 28 - System Service

www.DaikinENVi.comDaikin AC (Americas), Inc.1645 Wallace Drive, Suite 110Carrollton, TX 75006 USAIM-TS1-1-1305

Page 30 - List of Alerts

GETTING STARTED WelcomeThe Daikin ENVi thermostat kit has been designed to ensure the installation process is simple and ecient. This step-by-step In

Page 31

Package ContentsThe Daikin ENVi thermostat kit includes the following items. ENVi Thermostat Trim PlateDPCA with Power CableDouble-Sided AdhesiveScrew

Page 32

Before You BeginThis product is intended to be installed by trained service professionals.This manual explains the procedures for installing the Daiki

Page 33

Daikin System CompatibilityThe Daikin ENVi thermostat is designed to operate only with the Daikin Heat Pump and Cooling Indoor Units where the BRC944

Page 34 - IM-TS1-1-1305

pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential install