SiUS041111 Outdoor Unit: 15/18/24 Class
Removal Procedure 203
18 Disconnect the
connector for the
overload protector
[S40].
When reassembling, insert the
clamps of harnesses as below.
When reassembling, connect
the connectors in the following
order.
(1) [S40]
(2) [S20]
(3) [S80]
(4) [S70]
19 Pull out the clamp. The compressor harness has a
clamp.
When reassembling, insert the
clamp as below.
20 Disconnect the relay
connector for the
compressor.
21 Release the harness of
the relay connector
from the wire saddle.
Step Procedure Points
(R14310)
[S40]
[S40]
[S80]
[S20]
(R14363)
(R14311)
(R14725)
Compressor harness
(red, blue, yellow)
(R14312)
(R14313)
Page view 210