2.3
7,800
2,000
2.5
8,500
Galvanised steel plate
2,200
116/83
305
X
775
X
600
26
6.4
12.7
VP25 (External Dia, 32/Internal Dia, 25)
BYBC32G-W1
White (10Y9/0.5)
53
X
1,030
X
680
8.0
2.9
9,900
2,500
3.2
10,900
2,800
150/108
305
X
775
X
600
26
6.4
12.7
53
X
1,030
X
680
8.0
3.7
12,600
3,200
4.0
13,600
3,400
150/108
305
X
775
X
600
26
6.4
12.7
53
X
1,030
X
680
8.0
4.7
16,000
4,000
5.0
17,100
4,300
200/150
305
X
990
X
600
31
6.4
12.7
BYBC50G-W1
53
X
1,245
X
680
8.5
5.8
19,800
5,000
6.3
21,500
5,400
200/150
305
X
990
X
600
32
6.4
12.7
53
X
1,245
X
680
8.5
7.3
24,900
6,300
8.0
27,300
6,900
275/216
305
X
1,175
X
600
35
9.5
15.9
BYBC63G-W1
53
X
1,430
X
680
9.5
9.3
31,700
8,000
10.0
34,100
8,600
433/350
305
X
1,665
X
600
47
9.5
15.9
BYBC125G-W1
53
X
1,920
X
680
12.0
14.5
2.2 2.8 3.6 4.5 5.6 7.1 9.0 14.0
49,500
12,500
16.0
54,600
13,800
550/416
34/29 36/30 36/30 37/32 37/32 39/34 41/36 46/40
305
X
1,665
X
600
48
9.5
15.9
53
X
1,920
X
680
12.0
Heating capacity
kW
Btu/h
kcal/h
Casing
1-phase, 220-240 V/220 V, 50/60 Hz
Airflow rate (H/L)
/s
Sound level (H/L)
240 V dB(A)
0.077 0.092 0.092 0.130 0.130 0.161 0.209 0.256
0.044 0.059 0.059 0.097 0.097 0.126 0.176 0.223
7/5 9/6.5 9/6.5 12/9 12/9 16.5/13 26/21 33/25m
3
/min
Power
consumption
kW
Cooling
Heating
MODEL
Cooling capacity
kW
(*1)
(*2)
Btu/h(*1)
kcal/h(*1)
Power supply
Dimensions (H
X
W
X
D) mm
Machine weight kg
Piping
connections
Drain
Panel
(Option)
Model
Colour
mm
Dimensions (H
X
W
X
D)
Weight kg
Liquid (Flare)
Gas (Flare)
mm
kW
(*1)
Btu/h(*1)
kcal/h(*1)
(*2)
Power supply
Cooling capacity
MODEL
Dimensions (H
X
W
X
D) mm
Machine weight kg
Piping
connections
Drain
Panel
(Option)
Model
Colour
mm
kg
Dimensions (H
X
W
X
D)
Liquid (Flare)
Gas (Flare)
mm
Weight
FXKQ25MAVE
2.9
9,900
2,500
3.2
10,900
Galvanised steel plate
2,800
183/150
Heating capacity
kW
Btu/h
FXKQ32MAVE
3.7
12,600
3,200
4.0
13,600
3,400
FXKQ40MAVE
4.7
16,000
4,000
5.0
17,100
4,300
FXKQ63MAVE
7.3
2.8 3.6 4.5
7.1
24,900
6,300
8.0
27,300
6,900
183/150 216/166 300/250
kcal/h
Casing
1-phase, 220-240 V/220 V, 50/60 Hz
Airflow rate (H/L)
/s
215
X
1,110
X
710
31
6.4
12.7
VP25 (External Dia, 32/Internal Dia, 25)
BYK45FJW1
White (10Y9/0.5)
70
X
1,240
X
800
8.5
215
X
1,110
X
710
31
6.4
12.7
70
X
1,240
X
800
8.5
215
X
1,110
X
710
31
6.4
12.7
70
X
1,240
X
800
8.5
215
X
1,310
X
710
34
9.5
15.9
BYK71FJW1
70
X
1,440
X
800
9.5
40/35 40/35 42/36 44/39
Sound level (H/L)
240 V
dB(A)
Power
consumption
kW
Cooling
Heating
0.066 0.066 0.076 0.105
0.046 0.046 0.056 0.085
11/9 11/9 13/10 18/15
m
3
/min
Note: Specifications are based on the following conditions;
•Cooling: (*1) Indoor temp.: 27°CDB, 19.5°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
(*2) Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
Sound level: (FXCQ-M) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
(FXKQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Page view 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 39 40

Comments to this Manuals

No comments