Installation EDUS39-600-F7
16 FXLQ-M / FXNQ-M
1. SAFETY CONSIDERATIONS
Read these “SAFETY CONSIDERATIONS” carefully before
installing air conditioning equipment, and be sure to install it
correctly. After completing the installation, make sure that the
unit operates properly during the start-up operation.
Instruct the customer how to operate and maintain the unit.
Inform customers that they should store this Installation Man-
ual with the Operation Manual for future reference.
Always use a licensed installer or contractor to install this
product. Improper installation can result in water or refrigerant
leakage, electrical shock, fire, or explosion.
Meanings of DANGER, WARNING, CAUTION, and NOTE
symbols:
DANGER .............. Indicates an imminently hazardous
situation which, if not avoided,
results in death or serious injury.
WARNING ............ Indicates a potentially hazardous sit-
uation which, if not avoided, could
result in death or serious injury.
CAUTION ............. Indicates a potentially hazardous sit-
uation which, if not avoided, may
result in minor or moderate injury. It
may also be used to alert against
unsafe practices
NOTE .................... Indicates situations that may result
in equipment or propertydamage
accidents only.
Do not ground units to water pipes or telephone
wires because incomplete grounding could cause a
severe shock hazard resulting in severe injury or
death. Do not ground ss to lightning rods because
lightning strikes can cause a severe shock hazard
resulting in severe injury or death. Do not install unit
in an area where flammable materials are present
due to risk of explosion resulting in serious injury or
death.
Do not ground units to gas pipes because a gas leak
can result in an explosion causing serious injury or
death.
Refrigerant gas is heavier than air and displaces oxy-
gen. A massive leak can lead to oxygen depletion,
especially in basements, and an asphyxiation hazard
could occur leading to serious injury or death.
If the refrigerant gas leaks during installation, venti-
late the area immediately.
Refrigerant gas may produce toxic gas if it comes in contact
with fire such as from a fan, heater, stove, or cooking
device. Exposure to this gas could result in severe injury or
death.
After completing the installation work, check that the
refrigerant gas does not leak.
Refrigerant gas can produce toxic gas if it comes in contact
with fire such as from a fan, heater, stove, or cooking
device. Exposure to this gas can cause in severe injury or
death.
Children playing with plastic bags face the danger of
death by suffocation. Tear apart and throw away
plastic packaging so that children will not play with
them.
Safely dispose of the packing materials. Packing
materials, such as nails and other metal or wooden parts,
may cause stabs or other injuries.
WARNING
Ask your dealer or an authorized personnel to carry out
installation work. Do not try to install the unit by your-
self.
Improper installation may result in water leakage, electric
shocks, or fire.
Perform installation work in accordance with this
installation manual.
Improper installation may result in water leakage, electric
shocks, or fire.
Be sure to use only the specified accessories and
parts for installation work.
Failure to use the specified parts may result in water leak-
age, electric shocks, fire, or the unit falling.
Install the air conditioner on a foundation strong
enough to withstand the weight of the unit.
A foundation of insufficient strength may result in the equip-
ment falling and causing injuries.
Carry out the specified installation work after taking
account of strong winds, typhoons, or earthquakes.
Improper installation work may result in the equipment fall-
ing and causing accidents.
Make sure that a separate power supply circuit is
provided for this unit and that all electrical work is
carried out by an authorized personnel according to
local laws, regulations, and this installation manual.
An insufficient power supply capacity or improper electrical
construction may lead to electric shocks, or fire.
Make sure that all wiring is secured, the specified
wires are used, and no external forces act on the ter-
minal connections or wires.
Improper connections or installation may result in fire.
When wiring the power supply and connecting the
remote controller wiring and transmission wiring,
position the wires so that the electric parts box lid
can be securely fastened.
Improper positioning of the electric parts box lid may result
in electric shocks, fire, or the terminals overheating.
Before touching electrical parts, turn off the unit.
Do not touch the switch with wet fingers.
Touching a switch with wet fingers can cause electric
shock.
Be sure to install an earth leakage breaker.
Failure to install a ground leakage breaker may result in
electric shocks, or fire.
Do not install the air conditioner where the following
conditions exist:
(a) Mineral oil mist or an oil spray or vapor is produced, for
example in a kitchen.
Plastic parts may deteriorate and fall off or water may
leak.
(b) Corrosive gas, such as sulfurous acid gas, is produced.
Corroding copper pipes or soldered parts can cause
refrigerant leaks.
(c) Machinery is emitting electromagnetic waves.
Electromagnetic waves may disturb the operation of the
control system and result in a malfunction of the equip-
ment.(d) Where flammable gases may leak, where
there are carbon fiber or ignitable dust suspensions in
Page view 16