6L(1 :LULQJ'LDJUDPVIRU5HIHUHQFH
$SHQGL[ 
);)4000000009(
3D039600
Note:3
Notes)
1.
: Terminal
: Field wiring
: Connector
2. In case using central remote control, connect it to the unit in accordance
with the attached installation manual.
3. X24A is connected when the infrared remote control kit is being used.
4. When connecting the input wires from outside, forced off or on/off control
operation can be selected by remote control. In details, refer to the
installation manual attached the unit.
5. Remote control model varies according to the combination
system, confirm engineering data and catalogs, etc. Before
connecting.
6. Confirm the method of setting the selector switch (SS1, SS2) of
wired remote control and wireless remote control by installation
manual and engineering data, etc.
7. Symbols shows as follows.
PNK:PINK WHT:White YLW:Yellow
ORG:Orange GRY:Gray BLU:Blue BLK:Black RED:Red BRN:Brown
GRN:Blue
Indoor unit
A1P Printed circuit board
(Power supply)
A2P Printed circuit board
(Control)
A4P Printed circuit board
(Temperature sensor unit)
F1U Fuse ( B, 5A, 250V)
HAP Light emitting diode
(Service monitor-green)
KPR Magnetic relay (M1P)
M1F Motor (Indoor fan)
M1P Motor (Drain pump)
M1S Motor (Swing flap)
R1T Thermistor (Air)
R1T Thermistor (Coil-liquid)
R1T Thermistor (Coil-gas)
S1L Float switch
X1M Terminal strip
X2M Terminal strip
Y1E Electronic
expansion valve
Z1F Noise filter
Power circuit
Receiver/Display unit (attached
to infrared remote control
A5P Printed circuit board
A6P Printed circuit board
BS1 Push button (On/Off)
H1P Light emitting diode
(On-red)
H2P Light emitting diode
(Timer-green)
H3P Light emitting diode
(Filter sign-red)
H4P Light emitting diode
(Defrost-orange)
SS1 Selector switch
(Main/Sub)
SS2 Selector switch
(Wireless address set)
Connector for optional parts
X24A Connector
(Infrared remote control)
X33A Connector
(Adapter for wiring)
X35A Connector (Group
control adapter
Wired remote control
R1T Thermistor (Air)
SS1 Selector switch (Main/Sub)
Input from outside
Note-4
Transmission wiring
central remote control
Note-2
Wired remote control
Power supply
Switch box
(Indoor unit)
Receiver/Display unit
(Infrared remote control)
Page view 265