Daikin FTXN15KVJU Installation Manual Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 14
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
English 9
English
4.
Laying piping, hoses, and wiring
4-1. Right-side, right-back, or right-bottom piping
1) Attach the drain hose to the underside of the refrigerant pipes with
an adhesive vinyl tape.
2) Wrap the refrigerant pipes and drain hose together with insulation
tape.
3) Pass the drain hose and refrigerant pipes through the wall hole, then
set the indoor unit on the mounting plate hooks by using the
markings at the top of the indoor unit as a guide.
4-2. Left-side, left-back, or left-bottom piping
1) Replace the drain plug and drain hose.
2) Attach the drain hose to the underside of the refrigerant pipes
with adhesive vinyl tape.
3) Be sure to connect the drain hose to the drain port in place of a
drain plug.
4) Shape the refrigerant pipes along the pipe
path marking on the mounting plate.
5) Pass drain hose and refrigerant pipes
through the wall hole, then set the indoor
unit on mounting plate hooks, using the
markings at the top of indoor unit as a
guide.
6) Pull in the inter-unit wire.
7) Connect the inter-unit pipes.
8) Wrap the refrigerant pipes and drain hose together with insulation tape as
right figure, in case of setting the drain hose through the back of the indoor
unit.
9) While exercising care so that the inter-unit wire do not catch indoor unit,
press the bottom edge of indoor unit with both hands until it is firmly
caught by the mounting plate hooks. Secure indoor unit to the mounting
plate with indoor unit fixing screws 3/16 × 1/2 inch (M4 × 12mm).
Right-bottom
piping
Right-side piping
Right-back piping
Bind coolant pipe
and drain hose
together with
insulating tape.
Remove pipe port cover
here for right-side piping.
Remove pipe port cover
here for right-bottom piping.
Mounting plate
A
Remove pipe port cover here for left-bottom piping.
Remove pipe
port cover
here for left-
side piping.
Left-bottom piping
Left-side
piping
Left-back
piping
How to set drain plug.
No gap.
Do not apply lubricating
oil (refrigeration oil)
when inserting.
Application of causes
deterioration and drain
leakage of the plug.
Insert a hexagonal wrench 3/16” (4mm).
Drain
hose
Caulk this hole
with putty or
caulking material.
Bind with vinyl
tape.
A
Mounting plate
Wrap insulating tape around the
bent portion of refrigerant pipes.
Overlap at least half the width of
the tape with each turn.
Refrigerant
pipes
Drain hose
Bottom frame
H Indoor unit fixing screw
3/16” × 1/2” (M4 × 12mm)
(2 point)
Mounting
plate
A
Inter-unit wire
01_EN_3P276866-2D.fm Page 9 Friday, February 18, 2011 4:07 PM
Page view 9
1 2 ... 5 6 7 8 9 10 11 12 13 14

Comments to this Manuals

No comments