Heat Reclaim Ventilation
Heat Reclaim Vantilation
Improved E nthalpy E fficienc y
Higher E xternal S tatic P res s ure
E nhanc ed E nergy S aving F unc tions
1
2
41 42
Exhaust
heat
Exhaust
heat
The indoor accumulated heat is discharged at night.
This reduces the air conditioning load the next day thereby increasing efficiency.
Indoor
unit
Indoor
unit
Cold air
Generated
heat
Heat is discharged. The load is small so the temperature is rapidly reduced
to a comfortable level.
*Interlocked operation with an air conditioner
Comfortable!Comfortable!
Nighttime free cooling operation
*1
Air conditioning load reduced by approximately 30%!Air conditioning load reduced by approximately 30%!
This unit recovers heat energy lost through ventilation and
curbs room temperature changes caused by ventilation,
thereby conserving energy and reducing the load on the air
conditioning system.
Molecule of water
Miscellaneous gas
CO2 molecule, etc.
40 µm
High-humidity air
Low-humidity air
Permselective
film
Precise, thin-film
material
Exhaust air
Supply air
Sheet structure
Outdoor
Exhaust air
SA
Indoor
RA
(unclean
indoor air)
Outdoor air
(fresh air)
Total heat exchange ventilation
Enthalpy efficiency drastically improved by employing
newly developed ultra-thin film element! (VAM-GJ model)
Thickness of
the partition sheet
Due to the thinner film…
•Decreases the moisture resistance of the partition sheets
drastically.
•Realises more space for extra layers in the element,
resulting in increased effective area that supply and
exhaust air can be exposed to.
Moisture absorption increased by approx. 10%!
Moisture exchange efficiency is greatly improved by using optimised
thinner films and moisture-absorption materials in the element.
Furthermore, miscellaneous gas barrier properties are maintained by
decreasing the porosity in the moisture-absorption materials.
Automatically switches the
ventilation mode (Total
Heat Exchange
Mode/Bypass Mode)
according to the operating
status of the air conditioner.
Auto-ventilation Mode
Changeover Switching
Reduces air conditioning
load by not running the
HRV while air is still clean
soon after the air
conditioner is turned ON.
Pre-cool,
Pre-heat Control
Air conditioning sensible
heat load reduced by
appr ox. 5%
*2
!
20% 8%
2%
The air conditioning load reduction values are based on the following conditions;
Application: Tokyo office building
Building form: 2 floors above ground, 6 floors underground, floor area 2,100 m
2
Personnel density: 0.25 person/m
2
Ventilation volume: 25 m
3
/h
Indoor air conditioning level: summer 25°C 50% RH, intermediate seasons 24°C 50%
RH, winter 22°C 40% RH
Operating time: 2745 hours (9 hours per day, approx. 25 days per month)
Calculation method: simulation based on "MICRO-HASP/1982" of the Japan
Building Mechanical and Electrical Engineers Association.
VAM-GJ
Individual operation
Normal
ventilation fan
VAM-GJ
Interlocked operation
with air conditioner
Air conditioning load reduction (%)
20%
0%
Air Conditioning Load
Reduced by Approximately
30%
• The air conditioning load reduction values may vary according to weather and
other environmental conditions at the location of the machine's installation.
Nighttime free cooling operation is an energy-conserving function that works at night when air
conditioners are off. By ventilating rooms
containing office equipment that raises the
room temperature, nighttime free cooling
operation reduces the cooling load when
air conditioners are turned on in the
morning. It also alleviates feelings of
discomfort in the morning caused by heat
accumulated during the night.
Nighttime free cooling operation only works to cool and if connected to
Building Multi or VRV systems.
Nighttime free cooling operation is set to “off” in the factory settings, so if
you wish to use it, request your dealer to turn it on.
*1 This function can be operated only when interlocked with air conditioners.
*2 Value is based on the following conditions:
•Cooling operation performed from April to October.
•Calculated for air conditioning sensible heat load only
(latent heat load not included).
Energy ConservationCompact Equipment
Cold Climate Compatible
The HRV Creates a High-Quality Environment
by Interlocking with the Air Conditioner
306 mm
Air conditioning load reduced by approximately 30%!With a height of just 306 mm, the unit easily fits in limited
spaces, such as above ceilings.
-20 -10 0 10 20 30 40 50
50˚CDB-15˚CDB 50˚CDB-15˚CDB
*
*For VAM500GJVE
VAM150GJVE, VAM250GJVE, VAM350GJVE,
VAM500GJVE, VAM650GJVE, VAM800GJVE,
VAM1000GJVE, VAM1500GJVE, VAM2000GJVE
Model Numbers
Indoor unit
Daikin air conditioner
LCD remote controller
for indoor unit
• Operating mode signal
• Filter cleaning signal
• Failure detection signal
• ON/OFF signal
• Cooling/Heating mode signal
• Set temperature signal
• Ventilation signal
• Humidifier ON/OFF signal
HRV
InterlockingInterlocking
Standard operation at
temperatures down to -15°C.
This new series provides higher enthalpy efficiency , due to the greatly enhanced performance of the new ultra-
thin film element. Furthermore, improved external static pressure offers more flexibility for installation. Along
with these three outstanding improvements, Daikin’s exclusive function—nighttime free cooling
operation—contributes to energy conservation and more comfortable space.
1
2
For models: VAM150/250/350/650/800/1000/2000GJVE
For models: VAM150/350/500GJVE
2
1
OA
(Fresh air from
outdoors)
SA
(Supply air
to room)
EA
(Exhaust air to outdoors)
RA
(Return air
from room)
Compliant with the RoHS Directive*
* RoHS Directive: The RoHS (Restriction of Hazardous Substances (in electrical and electronic equipment)) Directive is an environmental directive enacted to regulate the use of designated
chemical substances (lead, cadmium, hexavalent chromium, mercury, polybrominated biphenyls and polybrominated diphenylether) in electrical equipment. All household
products subject to this Directive and sold in Europe from July 1, 2006 are legally bound to comply with the RoHS Directive.