Daikin RXS24DVJU Specifications Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
Certified Efficiency Performance Values
System
AHRI
Number
Combined With
Nominal cooling capacity EER
SEER
Nominal heating
capacity
COP
Low heating
capacity
COP
HSPF
Btu/h 95 °F Btu/h 47 °F Btu/h 17 °F
2MXS18GVJU
3059249 Non Ducted Indoor Unit 18,000 12.60 19.50 22,000 3.40 13,500 2.70 9.20
3059247 Ducted Indoor Unit 16,000 9.00 13.00 22,000 2.90 13,100 2.20 7.70
3059248 Mixed Ducted and Non Ducted Indoor Unit 17,000 10.80 16.30 22,000 3.15 13,300 2.45 8.50
3MXS24JVJU
3697115 Non Ducted Indoor Unit 24,000 12.50 16.60 30,000 3.20 19,300 3.2 9.00
3699491 Ducted Indoor Unit 23,400 9.70 13.00 29,000 2.70 18,100 2.7 7.70
3759750 Mixed Ducted and Non Ducted Indoor Unit 23,600 11.10 14.80 29,400 2.95 18,600 2.95 8.35
4MXS32GVJU
3059253 Non Ducted Indoor Unit 30,600 10.30 17.20 32,000 3.40 22,200 2.30 9.30
3059251 Ducted Indoor Unit 29,000 8.40 13.30 30,400 3.00 21,000 2.10 7.90
3059250 Mixed Ducted and Non Ducted Indoor Unit 29,800 9.35 15.25 31,200 3.20 21,600 2.20 8.60
Per AHRI, the certified ratings for variable-speed, multi-split systems are valid for all combinations of indoor units (based on
combination types) with the specific outdoor unit listed above and in the AHRI Directory of Certified Equipment.
Visit www.AHRIDirectory.org for further details and independent verification.
Any system that is a combination of ALL NON-DUCTED (CTXS and FTXS) indoor units achieves the SEER/EER/COP/HSPF listed on
the Non Ducted Indoor Unit line.
Any system that is a combination of ALL DUCTED (FDXS) indoor units achieves the SEER/EER/COP/HSPF listed on the Ducted
Indoor Unit line.
Any system that is a combination of MIXED DUCTED and NON-DUCTED indoor units achieves the SEER/EER/COP/HSPF listed on
the Mixed Ducted & Non Ducted Indoor Unit line.
2MXS18GVJU and 3MXS24JVJU in non
ducted combinations are Energy Star
rated and qualify for the Tax Relief Act
of 2010
Performance
TAX
CREDIT
QUALIFIED
24
Page view 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 30 31 32

Comments to this Manuals