To change the air ow rate setting
Press .
DRY mode AUTO or COOL or HEAT or FAN mode
The air ow rate setting is not variable.
Five levels of air ow rate setting from
” to “ ” plus “ ” and “ ” are available.
Indoor unit quiet operation
When the air ow is set to “
, the noise from the indoor unit will become quieter.
Use this when making the noise quieter.
The unit might lose capacity when the air ow rate is set to a weak level.
Each pressing of the button advances the air ow rate setting in sequence.
NOTE
Note on HEAT operation
Since this air conditioner heats the room by taking heat from outdoor air to indoors, the heating capacity becomes smaller in lower outdoor
temperatures. If the heating effect is insuf cient, it is recommended to use another heating appliance in combination with the air conditioner.
The heat pump system heats the room by circulating hot air around all parts of the room. After the start of HEAT operation, it takes some time
before the room gets warmer.
In HEAT operation, frost may occur on the outdoor unit and lower the heating capacity. In that case, the system switches into defrosting operation
to take away the frost.
During defrosting operation, hot air does not ow out of indoor unit.
Note on COOL operation
This air conditioner cools the room by blowing the hot air in the room outside, so if the outside temperature is high, the performance of the air
conditioner drops.
Note on DRY operation
The computer chip works to rid the room of humidity while maintaining the temperature as much as possible. It automatically controls temperature
and air ow rate, so manual adjustment of these functions is unavailable.
Note on AUTO operation
In AUTO operation, the system selects a temperature setting and an appropriate operation mode (COOL or HEAT) based on the room
temperature at the start of the operation.
The system automatically reselects setting at a regular interval to bring the room temperature to user-setting level.
If you do not like AUTO operation, manually change the set temperature.
Note on FAN operation
This is valid for fan only.
Note on air ow rate setting
At smaller air ow rates, the cooling (heating) effect is also smaller.