Page view 51
Photocatalytic Air Purifiers 51
SiENBE81-623A Removal Procedure
Procedure Points
(7) Remove the 3 screws
from the lock plate
and take out the fan
motor.
* The motor and the har-
ness are integrated
together.
* Make sure no washers
are left behind the fan.
Lock plate
Fan motor