Daikin RXS36HVJU Installation Manual Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
Quaternity Indoor Units - FTXG_HVJU Wall Mounted Units.
For use with RXG_HVJU Models
Model FTXG09HVJU FTXG12HVJU FTXG15HVJU
Cooling Capacity (min. - nom. - max.) Btu/h 5,300 - 9000 - 12,300 5,300 - 12,000 - 15,700 5,300 - 15,000 - 18,000
Heating Capacity (min. - nom. - max.) Btu/h 4,400 - 12,000 - 18,000 4,400 - 16,000 - 19,100 4,400 - 18,000 - 21,200
Heating Capacity at 17 °F Btu/h 8,100 10,800 12,200
Moisture Removal Pt/h 3.38 4.86 5.92
Airflow - Dry cfm 438 470 494
Sound Pressure Level - Cooling (H/M/L) dB(A) 42/33/26 43/35/27 45/37/29
Sound Pressure Level - Heating (H/M/L) dB(A) 42/35/28 43/36/29 44/38/31
Piping
Connections
Liquid (O.D.) in. 1/4 1/4 1/4
Gas (O.D.) in. 3/8 3/8 3/8
Condensate (O.D.) in. 11/16 11/16 11/16
Dimensions (H x W x D) in. 12 x 35 1/32 x 8 7/32
Weight lbs. 31 31 31
Wireless Remote Controller (standard) ARC447A3 ARC447A3 ARC447A3
Optional Condensate Pump DACA-CP1-1 DACA-CP1-1 DACA-CP1-1
Quaternity Outdoor Units - RXG_HVJU
For use with the FTXG_HVJU Models
Model RXG09HVJU RXG12HVJU RXG15HVJU
Compressor Type Hermetically sealed swing type compressor
Max. Fuse Size Amps 15 15 15
Energy Efficiency SEER 22 22 21
Energy Efficiency EER 15.8 14 12.9
Energy Efficiency HSPF 11 10.55 10
Energy Efficiency COP 4.51 4.04 3.99
Power Consumption - Cooling W 570 860 1,160
Power Consumption - Heating W 780 1,160 1,320
Sound Pressure Level (cooling/heating) dB(A) 46/46 49/48 50/50
Operating Range - Cooling (outdoor-db) °F 14 - 109 14 - 109 14 - 109
Operating Range - Heating (outdoor-db) °F -4 - 75 -4 - 75 -4 - 75
Operation Current - Cooling A 3.1 4.3 5.64
Operation Current - Heating A 4.04 5.64 6.36
Max. Piping Length ft. 33 33 33
Max. Height Difference ft. 26 26 26
Dimensions (H x W x D) in. 22 3/8 X 31 9/32 X 11 7/32
Weight lbs. 99 99 99
Room temperature 77°F
Humidity 80%
UNCOMFORTABLE
Hot and stuffy with high
humidity.
COMFORTABLE
Decreasing humidity while
maintaining the temperature
increases comfort.
Room temperature 77°F
Humidity 50%
Without Quaternity
86 104°F
86 104°F
COLD DRAFT
The room is over cooled
down to 70 °F to achieve
safisfactory dehumidificaion.
It results in an uncomfortable
cold sensation.
Room temperature 70°F
Humidity 45-50%
86 104°F
Standard
Unit
High Energy Efficiency and Low Estimated
National Average Annual Operating cost*
9,000Btu/h
Class
12,000Btu/h
Class
15,000Btu/h
Class
SEER 22 22 21
EER 15.8 14 12.9
Cooling cost
$44 $59 $77
HSPF 11 10.55 10
COP 4.51 4.04 3.99
Heating cost
$157 $246 $346
* All data is based on ARI 210/240 performance values
Warms air to
regulate temperature
Chills air to
remove moisture
Comfortable air at just
the right temperature
and humidity level
How is the Quaternity Dry Operation Achieved?
The evaporator of the indoor unit is divided into two
sections and solenoid valves are provided in between.
In cooling mode, the expansion valve between the
condenser and the evaporator works to send low-pres-
sure refrigerant to the indoor side, but in Quaternity
Dry Operation, the expansion valve is kept open and
a part of the indoor unit is used as a condenser by
working the solenoid valve.
Introducing Pichon-Kun
A mascot that represents Daikin’s innovative
thrust into the future. Created in Japan, this
dew droplet represents the fresh, natural, and
eco-friendly nature of Daikin’s products.
DEHUMIDIFICATION
without lowering the temperature
Dehumidification has many beneficial effects on comfort levels. During the summer, where there is an infiltration of high humidity
ambient air, even during mild ambient conditions, the room can feel very hot and stuffy. With “Quaternity controlled dehumidification”
the system controls the indoor humidity level by mixing the cool dry air with warm air via its intelligent indoor heat exchanger
technology. Also, this feature prevents inefficient overcooling, which helps to save on energy use.
11
All Quaternity systems qualify
for the U.S. Governments Tax
Rebate Stimulus package.
Page view 12