Daikin FTXG50JV1BA Datasheet Page 1

Browse online or download Datasheet for Split-system air conditioners Daikin FTXG50JV1BA. Daikin FTXG50JV1BA air conditioner User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
fTxg
Heat Pump
Series
Available in 0.75, 1.0, 1.4 ton
HOT STARTCOMFORTABLE
MODE
INTELLIGENT
EYE
WALL MOUNTED TYPE (HEAT PUMP) FTXG SERIES
Model Name
Indoor Unit FTXG25JV1BA FTXG35JV1BA FTXG50JV1BA
Outdoor Unit RXG25K3V1B RXG35K3V1B RXG50K3V1B
Capacity
Cooling Rated (Min - Max) Kw 2.5 (1.3~3.0) 3.5 (1.4~3.8) 5.0 (1.7~5.3)
Heating Rated (Min - Max) Kw 3.4 (1.3~4.5) 4.0 (1.4~5.0) 5.8 (1.7~6.5)
Power Supply 1phase, 220-240V, 50Hz
Running Current
(220-230-240V, 50Hz)
Cooling
Rated
A 3.2-3.0-2.9 5.1-4.8-4.6 7.2-6.9-6.6
Heating A 4.4-4.2-4.1 5.6-5.3-5.1 7.4-7.1-6.8
Power Consumption
Cooling
Rated
(Min - Max)
W 560 (350 - 820) 890 (360 - 1220) 1560 (450 - 1880)
Heating W 780 (320 - 1320) 990 (320 - 1500) 1600 (520 - 2500)
COP
Cooling
Rated
W/W 4.46 3.93 3.21
Heating W/W 4.36 4.04 3.63
Indoor Unit FTXG25JV1BA FTXG35JV1BA FTXG50JV1BA
Front Panel Colour Silver
Airflow rate
Cooling
m³/min 8.8 10.1 10.3
cfm 311 357 364
Heating
m³/min 9.6 10.8 11.4
cfm 339 389 402
Fan Speed 5 steps, quiet and Automatic
Sound Levels
(H/M/L/SL)
Cooling
dB (A)
38 / 32 / 25 /22 42 / 34 / 26 / 23 44 / 40 / 35 / 32
Heating 39 / 34 / 28 / 25 42 / 36 / 29 / 26 44 / 40 / 35 / 32
Dimensions (HxWxD) mm 295 x 915 x 155
Machine Weight kg 11
Outdoor Unit RXG25K3V1B RXG35K3V1B RXG50K3V1B
Casing colour Ivory White
Compressor Type Hermetically sealed swing type
Sound Levels (H/SL)
Cooling
dB (A)
46/43 48/44
Heating 47/44 48/45
Dimensions (HxWxD) mm 550 x 765 x 285 735 x 825 x 300
Machine Weight kg 34 48
Operation range
Cooling °CDB -10°C to 46°C
Heating °CWB -15°C to 20°C
Max. Piping Length
m
20 30
Max. Height Difference 15 20
Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27° CDB, 19° CWB; outdoor temp. 35° CDB; piping length 7.5 m.
2. Heating capacity is based on: indoor temp. 20° CDB; outdoor temp. 7° CDB, 6° CWB; piping length 7.5 m.
3. Sound levels are based on temperature conditions 1. and 2. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation
as a result of ambient conditions.
Page view 0
1

Summary of Contents

Page 1 - Heat Pump

fTxgHeat PumpSeriesAvailable in 0.75, 1.0, 1.4 tonHOT STARTCOMFORTABLE MODEINTELLIGENT EYEWALL MOUNTED TYPE (HEAT PUMP) FTXG SERIESModel NameIndoor Un

Comments to this Manuals