TECHNICAL DATA
Split-Sky Air
FDYP-B7
Concealed Ceiling Unit
Page view 0
1 2 3 4 5 6 ... 16 17

Summary of Contents

Page 1 - Split-Sky Air

TECHNICAL DATASplit-Sky AirFDYP-B7Concealed Ceiling Unit

Page 2 - Internet http://www.daikin.be

4Piping diagramsFDYP125B73TW23365-1(h/p) + 3TW23335-1(c/o)Indoor unitField piping J19.1 C122OT-OField piping J9.5 C122OT-OIndoor heat exchangerFilterO

Page 3 - TABLE OF CONTENTS

5Wiring diagrams2TW22806-1FDYP125,200,250B7A1P Printed circuit boardA2P Printed circuit board (transformer 220-240V/16V)T1R Printed circuit board (tra

Page 4 - 13x 3 6)6

6Sound level6-1Sound level dataSound pressure level (dB)Sound pressure level (dB)Octave band center frequency (Hz) Octave band center frequency (Hz)Oc

Page 5 - Specifications

7Fan characteristics3TW22808-1FDYP125B7V1FDYP200B7V13TW22818-1FDYP250B7V13TW22828-1highmediumlowhighmediumlowhighmedium• Concealed Ceiling Unit • R-40

Page 6

8Accessories8-1Standard accessoriesName of optionKit nameFDYP125B7 FDYP200B7 FDYP250B7Wiring adaptor for electrical appendices KRP4A51Adaptor for wiri

Page 7

9Control systems9-1Remote controlBRC1B527Fig. 1BRC1B527• Concealed Ceiling Unit • R-407C • FDYP125-250B7V1899-113• Split - Sky Air • Indoor Units

Page 8

Name and function of each switch and display onthe remote control1ON/OFF BUTTONPress the button and the system will start. Press the button again andt

Page 9 - Dimensional drawings

10InstallationNumber Description1 Indoor unit2 Outdoor unit3 Remote control4 Inlet air5 Discharged air6 Refrigerant piping, connection electric wire7

Page 10 - Piping diagrams

Split Sky AirZandvoordestraat 300, B-8400 OostendeInternet http://www.daikin.beDaikin units comply with the European regulations that guarantee the sa

Page 11 - Wiring diagrams

TABLE OF CONTENTSFDYP-B71 Features ... 22 Specificat

Page 12 - Sound level

1Features+ Compact casing with a height of 350mm (125 class) or450mm (220 and 250 class)+ Extremely quiet in operation both indoors and outdoors+ Fits

Page 13 - Fan characteristics

2SpecificationsNOMINAL CAPACITY and NOMINAL INPUTFor indoor units only:INDOOR UNITS FDYP125B7V1 FDYP200B7V1 FDYP250B7V1NOMINAL INPUT Cooling kW −−−For

Page 14 - Accessories

ELECTRICAL SPECIFICATIONSFor indoor units only: FDYP125B7V1 FDYP200B7V1 FDYP200B7V1CURRENT Nominal runningcurrentcoolingA −−−For combination indoor un

Page 15 - Control systems

NOMINAL CAPACITY and NOMINAL INPUTFor indoor units only:INDOOR UNITS FDYP125B7V1 FDYP200B7V1 FDYP250B7V1NOMINAL INPUT Cooling kW −−−Heating kW −−−For

Page 16

ELECTRICAL SPECIFICATIONSFor indoor units only: FDYP125B7V1 FDYP200B7V1 FDYP250B7V1CURRENT Nominal runningcurrentcoolingA −−−heatingA −−−For combinati

Page 17 - Installation

3Dimensional drawingsFDY(P)125B7view Aview ANotes:P: Service space: Extra service space for optionaldrain pump1Power supply intake2 Drain connection J