- Cooling Only -D-SeriesED 01 - 505
ED01-505 DimensionsRoom Air Conditioners D-Series 95.2 Outdoor UnitsR25DV1R35DV1DRAIN OUTLET( I. Dφ15. 9 HOSE FOR CONNECTION )33194706954204-HOLES FOR
Wiring Diagrams ED01-50510 Room Air Conditioners D-Series6. Wiring Diagrams6.1 Indoor UnitsFT25DVM / FT35DVMWIRELESSREMOTECONTROLLERPCB3LED2H2PLED1H1P
ED01-505 Wiring DiagramsRoom Air Conditioners D-Series 116.2 Outdoor UnitsR25DV1R35DV1POWER SUPPLY220V-240V~ 50HzTO INDOOR UNIT231LN76°CTFUX2MX1M23LN1
Piping Diagrams ED01-50512 Room Air Conditioners D-Series7. Piping Diagrams7.1 Indoor UnitsFT25DVM FT35DVMC : 4D047912AFIELD PIPINGFIELD PIPING(6.4CuT
ED01-505 Piping DiagramsRoom Air Conditioners D-Series 137.2 Outdoor UnitsR25DV1R35DV19.5CuT7.9CuTCOMPRESSOROUTDOOR UNITPROPELLER FAN7.9CuT7.9CuTMHEAT
Capacity Tables ED01-50514 Room Air Conditioners D-Series8. Capacity Tables8.1 Cooling OnlyFT25DVM+R25DV1 3D049930Cooling (220V 50Hz)AFR 8.8BF 0.24 IN
ED01-505 Capacity TablesRoom Air Conditioners D-Series 15FT35DVM+R35DV1 3D049931Cooling (220V 50Hz)AFR 9.9BF 0.24 INDOORTEMPOUTDOOR TEMPERATURE(°CDB)2
Capacity Tables ED01-50516 Room Air Conditioners D-Series8.2 Capacity correction factor by the length of refrigerant piping (Reference)The cooling and
ED01-505 Operation LimitRoom Air Conditioners D-Series 179. Operation LimitR25DV1 / R35DV1Notes:on the following conditions.The graph is basedOutdoor
Sound Level ED01-50518 Room Air Conditioners D-Series10.Sound Level10.1 Measuring LocationNotes: 1. Operation sound is measured in an anechoic chamber
ED01-505Room Air Conditioners D-Series 1Split - SystemRoom Air ConditionersD - Series1. Features...
ED01-505 Sound LevelRoom Air Conditioners D-Series 1910.2 Octave Band Level10.2.1 Indoor Units10.2.2 Outdoor UnitsFT25DVM FT35DVM70602030504063 125 25
Electric Characteristics ED01-50520 Room Air Conditioners D-Series11.Electric Characteristics3D0499393D049940Power Supply COMP OFM IFMIndoor Unit Outd
ED01-505 Installation ManualRoom Air Conditioners D-Series 2112.Installation ManualSAFETY PRECAUTIONS• Read these Safety Precautions carefully to ensu
Installation Manual ED01-50522 Room Air Conditioners D-SeriesCHOOSING A SITEThe indoor unit should be sited in a place where:• the restrictions on ins
ED01-505 Installation ManualRoom Air Conditioners D-Series 23 E Remote controller holderIn sites with poor drainage, use block bases for outdoor unit
Installation Manual ED01-50524 Room Air Conditioners D-SeriesOutdoor Unit Installation GuidelinesWall facing one sideWalls facing two sidesWalls facin
ED01-505 Installation ManualRoom Air Conditioners D-Series 25Indoor UnitBORING A WALL HOLE AND INSTALLING WALL EMBEDDED PIPE21• For walls containing m
Installation Manual ED01-50526 Room Air Conditioners D-Series(4) Open the front grille, then open the service lid.(Refer to INSTALLATION TIPS.)(5) Pas
ED01-505 Installation ManualRoom Air Conditioners D-Series 274WIRING5DRAIN PIPING• Connect the drain hose, as described below.• When drain hose requir
Installation Manual ED01-50528 Room Air Conditioners D-SeriesOutdoor UnitINSTALLING OUTDOOR UNIT• For outdoor unit installation, see CHOOSING A SITE
Features ED01-5052 Room Air Conditioners D-Series1. FeaturesFeaturesStylish Flat DesignEnergy SavingQuiet OperationWipe-clean Flat PanelHealthy &
ED01-505 Installation ManualRoom Air Conditioners D-Series 29PURGING AIR AND CHECKING GAS LEAKAGE• If using additional refrigerant, perform air purgin
Installation Manual ED01-50530 Room Air Conditioners D-Series3P153869-2BDRAIN WORK6• If the drain port is covered by a mounting base or floor surface,
ED01-505 Operation ManualRoom Air Conditioners D-Series 3113.Operation Manual2•Keep this manual where the operator can easily find them.•Read this man
Operation Manual ED01-50532 Room Air Conditioners D-Series3•Do not stand or sit on the outdoor unit. Do not place any object on the unit to avoid inju
ED01-505 Operation ManualRoom Air Conditioners D-Series 334Names of partsIndoor UnitON/OFF14 13121157134628910
Operation Manual ED01-50534 Room Air Conditioners D-Series5Outdoor UnitIndoor Unit1. Air filter2. Air purifying filter with photocatalytic deodorizin
ED01-505 Operation ManualRoom Air Conditioners D-Series 356Remote Controller1. Signal transmitter:•It sends signals to the indoor unit.2. Display:• I
Operation Manual ED01-50536 Room Air Conditioners D-Series7Preparation Before OperationTo set the batteries1. Press with a finger and slide the fron
ED01-505 Operation ManualRoom Air Conditioners D-Series 378Preparation Before OperationTo operate the remote controller• To use the remote controller
Operation Manual ED01-50538 Room Air Conditioners D-Series9To set the clock1. Press “CLOCK button”.is displayed.blinks.2. Press “TIMER setting button
ED01-505 FeaturesRoom Air Conditioners D-Series 305RAG04- 7< Current Model >< Current Model >< New Model >< New Model >784mm80
ED01-505 Operation ManualRoom Air Conditioners D-Series 3910The air conditioner operates with the operation mode of your choice.From the next time on,
Operation Manual ED01-50540 Room Air Conditioners D-Series11To change the air flow rate setting5. Press “FAN setting button”.NOTEDRY mode COOL or FAN
ED01-505 Operation ManualRoom Air Conditioners D-Series 4112Adjusting the Air Flow DirectionYou can adjust the air flow direction to increase your com
Operation Manual ED01-50542 Room Air Conditioners D-Series13To adjust the vertical blades (louvers)Hold the knob and move the louvers.(You will find
ED01-505 Operation ManualRoom Air Conditioners D-Series 4314POWERFUL OperationPOWERFUL operation quickly maximizes the cooling effect in any operation
Operation Manual ED01-50544 Room Air Conditioners D-Series15TIMER OperationTimer functions are useful for automatically switching the air conditioner
ED01-505 Operation ManualRoom Air Conditioners D-Series 4516TIMER OperationTo use ON TIMER operation• Check that the clock is correct. If not, set the
Operation Manual ED01-50546 Room Air Conditioners D-Series17CAUTIONIndoor unit, Outdoor unit and Remote controller1. Wipe them with dry soft cloth.F
ED01-505 Operation ManualRoom Air Conditioners D-Series 47181. Open the front panel. (page 17.)2. Pull out the air filters.•Push a little upwards the
Operation Manual ED01-50548 Room Air Conditioners D-Series19NOTECheckBefore a long idle period1. Operate the “Fan only” for several hours on a fine d
Features ED01-5054 Room Air Conditioners D-Series 05RAG04- 16Outdoor UnitIndoor UnitCurrentNewFT25/35BAVMCurrentFT25/35DVMNewR25/35JV1R25/35DV1Compati
ED01-505 Operation ManualRoom Air Conditioners D-Series 4920The following cases are not air conditioner troubles but have some reasons. You may just c
Operation Manual ED01-50550 Room Air Conditioners D-Series21Please check again before calling a repair person.Check again.Case CheckThe air conditione
ED01-505 Operation ManualRoom Air Conditioners D-Series 513P153868-2B22WARNING When an abnormality (such as a burning smell) occurs, stop operation a
Optional Accessories ED01-50552 Room Air Conditioners D-Series14.Optional Accessories14.1 Option ListNotes:+1 Wiring adaptor is also required for each
ED01-505 Optional AccessoriesRoom Air Conditioners D-Series 5314.2 Installation Manual14.2.1 KRP413A1S
Optional Accessories ED01-50554 Room Air Conditioners D-SeriesInstallationThis product is available in two types. The KRP413A1S is for installation in
ED01-505 Optional AccessoriesRoom Air Conditioners D-Series 55
Optional Accessories ED01-50556 Room Air Conditioners D-Series
ED01-505 Optional AccessoriesRoom Air Conditioners D-Series 5714.2.2 KPW937A4b)Checking the partsInstallation of LouverCAUTIONLouver1piece1pieceShapeQ
ED 01-505Printed in Japan 05/2005 B AK
ED01-505 Power SupplyRoom Air Conditioners D-Series 52. Power SupplyNotes: Power Supply Intake ; Outdoor UnitIndoor Units Outdoor Units Power SupplyFT
Functions ED01-5056 Room Air Conditioners D-Series3. FunctionsCategory FunctionsFT25·35DVMR25·35DV1Category FunctionsFT25·35DVMR25·35DV1Basic Function
ED01-505 SpecificationsRoom Air Conditioners D-Series 74. Specifications220/240V, 50HzNotes: MAX. interunit piping length: 25m MAX. interunit height
Dimensions ED01-5058 Room Air Conditioners D-Series5. Dimensions5.1 Indoor UnitsFT25DVMFT35DVMWIRELESS REMOTE CONTROLLERLEFTBOTTOMTHE MARK (→) SHOWS P
Comments to this Manuals